Quick verdict
Buy the 105 when a laundry tray, wet bar or basement lavatory sits below the nearest drain and you want a sealed, vented box rather than an open pit. Its cast iron M53 pump is the same one Zoeller sells for sump duty, so it shrugs off lint. It is built for gray water only; a toilet needs a sewage system.
Who it fits, and who should skip it
A good fit if
- A laundry tray or utility sink in a basement sits below the house drain.
- You want the basin, pump, discharge pipe and check valve to arrive as one assembly.
- Your lift to the drain line stays near 10 ft, where the maker's table shows 34 GPM.
Look elsewhere if
- The fixture is a toilet; this basin is for gray water, not raw sewage.
- The water you drain runs hotter than 130 °F, the rating Zoeller gives the 105.
Specifications
Pump
| Pump inside | Zoeller M53 (listed as 105 (M53) on the data sheet) |
|---|---|
| Horsepower | 3/10 HP |
| Voltage | 115 V, single phase, 60 Hz |
| Full-load amps | 9.7 A |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series.
Performance
| Max flow | 43 GPM (163 LPM) at 5 ft |
|---|---|
| Flow at 10 ft | 34 GPM |
| Flow at 15 ft | 19 GPM |
| Max head | 19.25 ft (5.9 m) shut-off head |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series.
Switch
| Switch type | Automatic, float-operated mechanical switch |
|---|---|
| On / off levels (M53 pump) | On at 7-1/4 in, off at 3 in |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series; Zoeller technical data sheet FM2778, Mighty-Mate series.
Basin
| Basin | Polypropylene, 14-1/2 in diameter, 12-1/2 in tall |
|---|---|
| Inlets | 1-1/2 in compression slip fit, top and side |
| Discharge | 1-1/2 in NPT |
| Vent | 2 in NPT |
| Check valve | PVC full-flow check valve with slip union, included |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series.
Build
| Solids handling | 1/2 in, non-clogging vortex impeller |
|---|---|
| Max liquid temperature | 130 °F (54 °C) |
| Power cord | 9 ft, 3-wire cord and plug |
| Shipping weight | 30 lb (14 kg) |
| Codes | Meets UPC; complies with ASME A112.3.4 and CSA B45.9 |
| Warranty | 36 months limited (data sheet) |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series; Zoeller installation instructions FM2113, preassembled drain pump system.
Versions
The basin is shared with the Model 132, which carries the smaller M72 pump. The 105 is the version with the cast iron M53.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| 105, automatic, 115 V | 105-0001 | M53 pump, 3/10 HP, 9.7 A, 9 ft cord, check valve included | View on Amazon |
| 132, automatic, 115 V | 132-0001 | M72 pump, 1/3 HP, 3.1 A, 3/8 in solids, rated for 110 °F | Not linked |
Figures: Zoeller technical data sheet FM2801, Drain Pump Series; Amazon listing B0009TCDZ2.
Installation and setup
Set the basin on a firm, level floor beside the fixture it serves. The sink or tray drains into one of the 1-1/2 in inlets through a trap you supply, because Zoeller designed this unit for an external trap. The 2 in vent connection must be piped to the building's vent system; the maker rules out automatic air admittance devices of the Pro-Vent type.
The discharge leaves through 1-1/2 in pipe with the check valve and union included, so keep the line at that size or larger. Leave a way to disconnect the basin from the plumbing for later service.
Plug the cord into a grounded outlet protected by a GFCI, and never through an extension cord. On the first start, let a few gallons sit so the packing peanuts dissolve, then fill slowly and watch every joint for leaks.
Switch and sizing notes
The switch belongs to the M53 pump inside the basin. Zoeller's M53 sheet puts the start point at about 7-1/4 in of water and the stop at about 3 in, and those levels cannot be changed. In a small basin that means short, frequent runs while a washing machine drains, which is normal.
To check the lift, measure from the basin floor to the highest point the pipe reaches, then add an allowance for the length of the run. The data sheet table gives 43 GPM at 5 ft, 34 GPM at 10 ft and 19 GPM at 15 ft, with no flow left at 19.25 ft. The sizing calculator adds pipe friction for you.
Compatibility
Zoeller lists the same basin footprint for the 132, so a worn 105 basin can carry on with a replacement pump. The data sheet's replacement table names item 007917 as the M53 pump, while the installation sheet's parts breakdown lists 156805 for current 105 units; quote the date code from the lid label when you order. The sink and laundry drain guide covers when a separate pump is the better fix.
Ownership and maintenance
Run the unit at least once a month, as the installation sheet asks, by filling the fixture and watching the pump start and stop. Never unplug the pump to use the basin as a holding tank.
The data sheet lists a 36-month limited warranty for the 105, but the printed warranty in the installation sheet reads one year from purchase. Keep the receipt and ask Zoeller which term applies to your unit.
Pros and cons
Pros
- Basin, pump, discharge pipe and check valve arrive preassembled.
- Cast iron M53 pump with a vortex impeller that passes lint.
- Top and side inlets suit cabinets of different layouts.
- Meets UPC and the ASME and CSA drain-basin standards.
Cons
- Gray water only; not rated for toilets or raw sewage.
- Fixed switch levels mean short cycles in the small basin.
- Warranty term differs between two of Zoeller's own documents.
Alternatives worth comparing



Compared with and featured in
Final verdict
The 105 is the simple answer for a below-drain sink or laundry tray: one box, a proven cast iron pump and code approvals already printed on the sheet. Keep it to gray water, keep the vent connected and check that your lift stays well under the 19.25 ft shut-off head.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Can the Zoeller 105 handle a toilet?
No. Zoeller sells it for laundry trays, wet bar sinks, lavatories, dehumidifiers and air conditioning condensate, and states that dewatering pumps are not meant for raw sewage. A basement toilet needs a sewage basin with a pump that passes 2 in solids, or an upflush macerating unit.
Does the 105 need a vent?
Yes. The basin has a 2 in NPT vent opening and the installation sheet says the unit must be vented to local code. It also rules out automatic plumbing vent devices, so tie the vent into the building's vent stack or run it outdoors as your inspector requires.
Can a dishwasher or washing machine drain into it?
The data sheet allows use with dishwashers and garbage disposals, and the vortex impeller passes laundry lint. Hot rinse water is the limit to watch: the 105 is rated for liquid up to 130 °F, so very hot discharges should mix with cooler water before they reach the basin.
What is the difference between the 105 and the 132?
Both use the same polypropylene basin. The 105 holds the cast iron M53 pump with 1/2 in solids handling and a 130 °F rating, while the 132 uses the lighter M72 pump, passes 3/8 in solids and is rated for 110 °F.