Category ยท Backup systems

Backup sump pumps

Systems that keep a sump pit draining when the power fails or the primary pump stops.

A backup pump shares the pit with your primary pump and starts only when the water rises past it. Battery systems run a 12 V pump from a deep-cycle or AGM battery and sound an alarm when something is wrong. Combination systems ship a new primary pump with the backup already attached. Water-powered units use city water pressure instead of a battery, so they need a municipal supply and no well.

Compare backups on the flow the maker lists at 10 ft, not at zero lift. Basement Watchdog's Special CONNECT, for example, drops from 2,600 GPH to 1,850 GPH at that height. The table below lists every system we cover with the maker's figures.

Start here

Before you buy

  • Budget for the battery. Most battery systems ship without one. The battery sets your runtime, so buy the type the maker recommends and replace it on schedule.
  • Check the pit width. Two pumps and two floats must fit side by side. Wayne asks for a 14 in basin for the ESP25n; compact units suit narrower pits.
  • Water-powered needs city water. These pumps run on household water pressure, so they do not work on a private well or when the municipal supply drops.
  • Mind the 12 V utility pump. A 12 V pump with clips is a portable utility tool, not a backup system; it has no charger, controller or alarm.

Every backup sump pump we cover

14 products
ImageProductTypeMax flow (maker)Max head (maker)Runtime (maker)Battery
Basement Watchdog Big Dog CONNECT BWD12-120C Battery Backup Sump Pump
Basement Watchdog
Battery backup58 GPM (3,500 GPH) at 0 ftNot stated by the maker; the highest rated point is 10 ftNot statedNot stated
Zoeller Aquanot 508 Battery Backup Sump Pump System
Zoeller
Battery backup40 GPM (listing figure)Not stated in the maker's table for this itemNot statedNot stated
Liberty Pumps 441 Battery Back-Up Sump Pump System
Liberty Pumps
Battery backupNot stated in the saved maker documents18 ft (5.5 m) maximum vertical pumping distanceNot statedNot stated
Superior Pump 91012 12 Volt Utility Pump
Superior Pump
Battery backup1,380 GPH at 0 ft22 ft on the product page; 20 ft on the listing1380 gallonsNot stated
Basement Watchdog Emergency (BWE) Battery Backup Sump Pump
Basement Watchdog
Battery backup2,000 GPH at 0 ftNot stated in the maker's manualNot statedNot stated
Basement Watchdog Special CONNECT (BWSP) Battery Backup Sump Pump
Basement Watchdog
Battery backup2,600 GPH at 0 ftNot stated in the maker's manualNot statedNot stated
Wayne ESP25n Battery Backup Sump Pump
Wayne
Battery backup2,700 GPH at 0 ftNot stated; the maker's table ends at 15 ft10,000 gallonsNot stated
Wayne ESP25 12 Volt Battery Backup Sump Pump System
Wayne
Battery backupNot stated in the maker's manual20 ft (listing figure)Not statedNot stated
Wayne WBPS50 Smart Sump Pump System with Battery Backup
Wayne
Primary + backup combo5,100 GPH (85 GPM)25 ft maximum lift (listing)Not statedNot stated
Basement Watchdog CITS-50 Combination Primary and Backup Sump Pump
Basement Watchdog
Primary + backup combo4,400 GPH primary at 0 ft (listing figure)Not stated in the maker's manualNot statedNot stated
Wayne WSS30VN Primary and Battery Backup Sump Pump System
Wayne
Primary + backup combo5,100 GPH (85 GPM) primary at 0 ftNot stated in the manual; its table ends at 15 ft10,000 gallonsNot stated
Liberty Pumps PC257-442 Combo Sump Pump System
Liberty Pumps
Primary + backup combo44 GPM at 5 ft (primary); backup 46 GPM at 12.1 V23 ft shut-off (primary)Not statedNot stated
Pumps-A-Lot WP25 Water-Powered Pump
Pumps-A-Lot
Water-powered backup800 GPHNot statedNot statedNot stated
Liberty SumpJet SJ10 Water-Powered Backup Pump
Liberty Pumps
Water-powered backup19.8 GPM (1185 GPH) at 60 PSI and 4 ft of liftNot statedNot statedNot stated

Figures are the makers' own; each product page lists them with their sources.

Questions readers ask

Do I need a backup sump pump?

If your basement has finished space or stored belongings, or your pump runs during most storms, a backup is worth it. Power cuts and switch failures are the usual causes of sump flooding, and a primary pump cannot cover either.