Quick verdict
The SJ10 suits a home on city water that wants a backup which never runs flat. As long as the mains keep their pressure, it keeps pumping through a long outage with no battery to charge or replace. The trade-offs are real: it needs an approved backflow preventer, it spends drinking water to move sump water, and its capacity depends on your pressure. It does nothing for a house on a private well during a power cut.
Who it fits, and who should skip it
A good fit if
- Your home is on a municipal supply holding 40 PSI or more with water flowing.
- You want an outage backup that does not depend on a charged battery.
- The pit is at least 18 in across, with room beside the main pump.
Look elsewhere if
- Your water comes from a well pump, which stops when the power does.
- The discharge lifts more than about 12 ft at modest supply pressure.
Specifications
Supply
| Power source | Municipal water pressure; no electricity needed to pump |
|---|---|
| Inlet pressure | Accepts 20 to 100 PSI; 30 PSI minimum recommended with water flowing |
| Inlet connection | 3/4 in NPT with SharkBite Max push fitting (PEX, copper, CTS CPVC) |
Figures: Liberty Pumps SJ10-Series sales literature LLIT004400; Liberty Pumps installation manual 5824000K, SumpJet; Liberty Pumps SumpJet SJ10-Series specifications SJ10_P1.
Performance
| Max flow | 19.8 GPM (1185 GPH) at 60 PSI and 4 ft of lift |
|---|---|
| Flow at 40 PSI | 15.4 GPM at 4 ft, 12.5 at 8 ft, 9.3 at 12 ft, 7.2 at 15 ft |
| Flow at 30 PSI | 12.8 GPM at 4 ft, 9 at 8 ft, 5.5 at 12 ft, none listed at 15 ft |
| Flow at 60 PSI, 15 ft | 13.5 GPM |
| Water used | Removes 2 gallons of sump water per gallon used, at a 5 ft lift |
Figures: Liberty Pumps SumpJet SJ10-Series specifications SJ10_P1; Liberty Pumps SJ10-Series sales literature LLIT004400.
Switch
| Switch type | Float-operated diaphragm valve with magnet, stainless float rod |
|---|
Figures: Liberty Pumps SumpJet SJ10-Series specifications SJ10_P1.
Build
| Discharge | 1-1/2 in |
|---|---|
| Backflow protection | Built-in inlet check valve plus foot valve; RP/RPZ device required per UPC |
| Construction | PVC body and pipe, ABS cover and float, stainless fasteners |
| Size and weight | 21.6 in tall, 5.1 in wide, 6 lb |
| Minimum pit diameter | 18 in |
| Max liquid temperature | 130 °F |
| Listing | cUPC listed to IAPMO PS 119 |
| Warranty | 3-year limited |
Figures: Liberty Pumps SumpJet SJ10-Series specifications SJ10_P1; Liberty Pumps installation manual 5824000K, SumpJet; Liberty Pumps SJ10-Series sales literature LLIT004400.
Versions
Three versions share the same pump; they differ only in how they tell you the backup has started.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| SJ10, no alarm | SJ10 | Standard water-powered backup | View on Amazon |
| SJ10A, with alarm | SJ10A | Pre-mounted float sensor and 120 V wall alarm, 86 dB, 9 V battery backup | Not linked |
| SJ10A-EYE, wireless alarm | SJ10A-EYE | NightEye alarm that sends app notices when the SumpJet runs | Not linked |
Figures: Liberty Pumps SJ10-Series sales literature LLIT004400; Liberty Pumps SumpJet SJ10-Series specifications SJ10_P1; Amazon listing B0013H94MO, Liberty SumpJet.
Installation and setup
The SJ10 clamps onto the existing discharge pipe with its stainless hose clamps and can face left or right. Liberty's manual puts its float a few inches above the level where the main pump switches on, which places the gray housing roughly 12 to 16 in above that point. That way it only wakes up when the main pump has failed or fallen behind.
Run a 3/4 in supply line from a cold water pipe, through an approved reduced-pressure backflow assembly, to the push fitting. Flush the line first, and keep any soldered copper joints 18 in or more from the body. Its discharge needs a separate route: never tie it into the main pump's pipe. Either leave a 1 in air gap or carry it outside, ending 6 to 24 in above the ground.
Switch and sizing notes
There is no motor. When the float rises, a magnet opens a diaphragm valve and mains water rushes through a nozzle and venturi, dragging sump water up with it. Output therefore rises with supply pressure and falls with lift. At 60 PSI Liberty lists 19.8 GPM at a 4 ft lift and 13.5 GPM at 15 ft; at 30 PSI the table stops at 12 ft with 5.5 GPM.
Measure your pressure at a hose bib with water flowing, not static. A backflow assembly costs some pressure too, so expect a little less than the table. Compare that figure with your storm inflow; the guide on battery versus water-powered backups sets out when each type makes sense.
Ownership and maintenance
With no battery, upkeep is short. Lift the float by hand now and then to confirm water flows and the valve closes cleanly, and clear debris from the float and the suction screen. Check that the backflow assembly is inspected as your water utility requires.
During a long outage, remember each cycle uses city water, at roughly one gallon for every two removed at a modest lift. Liberty warrants the SJ10 for three years from purchase.
Pros and cons
Pros
- No battery to charge, replace or run down.
- Keeps working through outages of any length on city pressure.
- Narrow 5.1 in body mounts on the existing pipe.
- Alarm and wireless alarm versions available.
Cons
- Useless on well water when the power is out.
- Requires a reduced-pressure backflow assembly.
- Capacity drops sharply at low pressure or high lift.
Alternatives worth comparing



Final verdict
On a city supply with healthy pressure, the SJ10 is the most hands-off outage backup available, because there is no battery to fail. Budget for the backflow assembly, check your flowing pressure against Liberty's table, and choose a battery system if you are on a well.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Does the SumpJet SJ10 need electricity?
Not to pump. The SJ10 runs entirely on municipal water pressure through a venturi. Only the alarm versions use power: the SJ10A has a 120 V wall alarm with a 9 V battery backup, and the SJ10A-EYE adds wireless notices, which need your router to be powered.
Will the SJ10 work with a well?
Liberty says no for power failures. The SumpJet needs an uninterrupted water supply, and a well pump stops when the electricity does. It could still cover a failed main sump pump while the power is on, but it is not an outage backup for a well-supplied house.
How much water does the SumpJet use?
Liberty's literature says it removes about 2 gallons of sump water for every gallon of supply water, measured at a 5 ft lift. Higher lifts or lower supply pressure reduce that ratio, so a long storm during an outage can draw a noticeable amount of city water.
Why does it need a backflow preventer?
The SJ10 connects drinking water to a sump pit. It has a built-in check valve and a foot valve, but Liberty states the UPC requires an approved reduced-pressure zone device as well, so pit water can never siphon back into the supply.