Quick verdict
Pick the CDS325 when a furnace, air handler or boiler drain must climb farther than the 20 ft that Aquastrong's CDS320 manages. Its body, float levels and inlets are described in the same words as that model, so the extra head is the whole case for it. The listing omits size, weight, voltage row and warranty term, which matters if the pump must fit a tight closet.
Who it fits, and who should skip it
A good fit if
- The drain tubing has to rise more than 20 ft, for example from a basement furnace up and over to a drain.
- You want a tank pump whose overflow leads can stop the equipment.
- A boiler, ice maker or dehumidifier shares the pump with the air handler.
Look elsewhere if
- A wall-mounted ductless unit that needs a pump hidden in the line set cover.
- You need the exact footprint before buying, which this listing does not give.
- Your climb is short, where the CDS320 already covers it.
Specifications
Performance
| Max flow | 95 GPH |
|---|---|
| Max head | 26 ft vertical lift |
| Flow at other heights | Not stated in the listing |
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Motor
| Voltage | Title says 115V/230V; no voltage spec row |
|---|---|
| Motor protection | Thermally protected motor |
| Horsepower | Not stated in the listing |
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Switch
| Switch type | Automatic, Hall sensor with float, plus a high-level safety switch |
|---|---|
| On / off levels | On at 2.28 in, off at 1.26 in |
| Safety switch leads | Two signal wires to the appliance; trips on high water |
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Build
| Reservoir | Removable, 1/2 gallon |
|---|---|
| Inlets | Five 1 in ports |
| Discharge | 2/5 in OD barb with internal check valve; fits 1/4 in to 3/8 in tubing |
| Power cord | 3.3 ft with 3-prong plug |
| Construction | Plastic body, vertical centrifugal pump, listed style Above Ground |
| Dimensions and weight | Not stated in the listing |
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Ownership
| Warranty | Not stated in the listing |
|---|
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Versions
One color and one configuration appear on the saved page for this model.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| CDS325, grey | CDS325 | Tank pump, 3.3 ft cord; tubing not listed as included | View on Amazon |
Figures: Amazon listing B0G6CQK5VG, Aquastrong CDS325.
Installation and setup
Set the reservoir on level ground or fix it to a wall so it stands plumb. A tilted tank lets the float hang and can fool both the pump sensor and the overflow sensor. Feed condensate lines into the 1 in inlets from above and plug any spare port.
The discharge is a small barb sized for 1/4 in to 3/8 in vinyl tubing, and the non-return valve sits inside it. On a run near the 26 ft rating, keep the tubing short and free of sags and kinks; every loop that holds water is extra work for a pump this small. Clamp the tubing at the barb so it cannot pop off when the motor starts.
The 3.3 ft cord ends in a 3-prong plug, so plan for a grounded receptacle within arm's reach. Wire the two safety leads into the air handler or furnace control circuit, not just to a buzzer, so the equipment stops when the tank backs up. If the unit is a boiler or ice maker, check that its controls accept a normally closed contact.
Switch and sizing notes
Switching works the same way as on Aquastrong's other tank pumps: a float in the reservoir is read by a Hall sensor, the motor starts at about 2.28 in of water and quits near 1.26 in. A separate high sensor opens the safety leads if water keeps rising past the start point.
The CDS325 is the taller-lift choice of the pair. Aquastrong lists 95 GPH and 26 ft, against 85 GPH and 20 ft for the CDS320, but publishes no curve for either, so flow at a real height is unknown. Measure the vertical rise from the pump to the highest point of the tubing. If that rise lands between roughly two-thirds of the rating and the rating itself, this model leaves more margin than the CDS320. Past 26 ft, neither pump will deliver.
Ownership and maintenance
Every six months at least, unplug the pump, take off the reservoir and wash the tank, float and filter basket. Coil slime and furnace scale build up quickly in a warm basement and are the usual cause of a stuck float.
While it is apart, look inside the outlet barb for grit that could hold the check valve open, since a leaking valve lets the line drain back and the pump short-cycles. Reassemble, pour in water, and lift the float to make sure the safety circuit stops the appliance. The saved listing does not give a warranty term, so ask the seller before relying on one.
Pros and cons
Pros
- Tallest listed lift of Aquastrong's tank pumps here at 26 ft.
- Overflow leads can shut the equipment down.
- Five inlets for several drains.
- Check valve sits inside the outlet.
Cons
- No size, weight or warranty figures on the listing.
- No flow curve, only the two end points.
- Catalog files it as a mini-split pump, but it is a full tank unit.
Alternatives worth comparing



Final verdict
The CDS325 makes sense only when the extra lift matters: a tank pump job where the tubing climbs past 20 ft. For shorter runs, the better-documented CDS320 does the same work, and for very tall runs a 45 ft pump is the safer choice.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is the Aquastrong CDS325 a mini-split pump?
No. Its listing describes a half-gallon removable reservoir, five large inlets and a vertical centrifugal pump, which is the tank layout used beside furnaces and air handlers. A true ductless mini pump, like Aquastrong's CDS036, has a tiny sensor tank that hides inside the line set cover.
How is it different from the CDS320?
The listing text is nearly the same, with the same float levels, inlets and outlet. The stated differences are performance: 95 GPH and a 26 ft lift for the CDS325, against 85 GPH and 20 ft for the CDS320. The CDS320 listing also gives size and warranty, which this one omits.
What voltage does it use?
The title says 115V/230V, but there is no voltage row and the cord ends in a 3-prong plug. Run it on an ordinary grounded household outlet and ask Aquastrong before connecting it to anything else.
Does it need a separate overflow alarm?
Not if you wire its two safety leads into the appliance controls, which stops condensate production when the tank fills. A standalone alarm can still help if the pump serves equipment that cannot accept a shut-off contact.