Quick verdict
This is a plain replacement for the boxy reservoir pump that sits beside a furnace or air handler. It has five inlets, a built-in check valve and a pair of overflow leads that can open the equipment's control circuit. The trade-off is information: Aquastrong gives no flow figures between the top rate and the shut-off height, so a long climb is guesswork.
Who it fits, and who should skip it
A good fit if
- You are replacing a worn tank pump next to a furnace, air handler or high-efficiency boiler.
- Your drain line rises well under 20 ft before it can fall to a drain.
- You want overflow leads that can shut the furnace or air handler down before the reservoir spills.
- Several appliances share one pump, which the five inlet ports allow.
Look elsewhere if
- A ductless head where there is no floor or wall space for a full-size reservoir.
- You need a published flow-versus-height table to size a long or tall run.
Specifications
Performance
| Max flow | 85 GPH (listed as 1.41 gpm) |
|---|---|
| Max head | 20 ft vertical lift |
| Flow at other heights | Not stated in the listing |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Motor
| Horsepower | 1/38 HP (title figure) |
|---|---|
| Voltage | 115 V spec row; title says 115V/230V; brand chart says 100V~230V |
| Motor protection | Thermally protected motor |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Switch
| Switch type | Automatic, Hall sensor with float; separate high-level safety switch |
|---|---|
| On / off levels | Starts at 2.28 in of water, stops at 1.26 in |
| Safety switch leads | Two signal wires (NC and COM) to cut the appliance on high water |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Build
| Reservoir | Removable, 1/2 gallon |
|---|---|
| Inlets | Five 1 in inlet ports |
| Discharge | 2/5 in OD barbed outlet with built-in check valve, for 1/4 in to 3/8 in tubing |
| Power cord | 3.3 ft, 3-prong plug |
| Dimensions | 11.3 in L x 5 in W x 4.9 in H (spec row) |
| Construction | Plastic housing, vertical centrifugal pump |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Ownership
| Cleaning interval | Reservoir, float and filter basket at least every six months |
|---|---|
| Warranty | 2-year warranty (listing warranty row) |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Versions
Aquastrong sells this tank pump bare or with a coil of vinyl tubing. Only the bare pump has a saved product page here.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| CDS320, pump only, gray | CDS320-1 | Tank pump with 3.3 ft cord; no drain tubing in the box | View on Amazon |
| CDS320 with tubing | Not stated in the listing | Same pump sold with 10 ft of vinyl tubing per the brand's comparison chart | Not linked |
Figures: Amazon listing B0BKZRN3ZG, Aquastrong CDS320-1.
Installation and setup
Mount the pump upright on a flat floor or wall surface; the listing is explicit that it must stand vertical, because both the pump float and the overflow sensor rely on the water rising straight up the reservoir. Bring the appliance drains into any of the five 1 in inlet ports and cap the ones you do not use so the tank does not vent smells or spill.
The outlet is a 2/5 in OD barb that takes 1/4 in to 3/8 in tubing, and the check valve is already inside it, so no extra valve is needed at the pump. Route the tubing up to its highest point first, then let it fall steadily to the drain. Plug the 3.3 ft cord into a grounded outlet close by; the short lead means the receptacle has to be within reach of the reservoir.
Finally, connect the two safety leads in series with the furnace or air handler control circuit, so the equipment stops if the tank fills. Our guide to choosing a condensate pump covers that wiring.
Switch and sizing notes
A float rides inside the reservoir and a Hall sensor reads it: the motor starts when water reaches about 2.28 in and stops near 1.26 in. A second, higher sensor drives the overflow circuit. Because that pair of leads is normally closed, it can sit in the thermostat or safety loop and open it when water climbs too far.
For sizing, the listing gives only two points: 85 GPH with no lift and a 20 ft maximum height, where flow falls to nothing. Real flow somewhere between those depends on your run, and Aquastrong does not publish the curve. Condensate volumes are small, so height is the real limit. Keep the climb comfortably below 20 ft, and if it approaches that, choose a pump with a taller rating.
Ownership and maintenance
Plan on cleaning the reservoir, the float and the filter basket at least every six months, as the listing asks. Slime from the coil and dust carried in with the water are what jam floats and block inlet screens, and a stuck float is how a tank pump floods a floor. With the pump unplugged, lift the reservoir off, rinse it and the basket, and check that the float moves freely.
After cleaning, pour water into an inlet and watch for a start, a stop and no drip at the barb. Then lift the float by hand to confirm the safety leads shut the appliance off. The listing's warranty row gives two years; keep the order record with the pump.
Pros and cons
Pros
- Overflow leads can stop the furnace or air handler before a spill.
- Five inlets let a furnace, coil and humidifier share one tank.
- Check valve is built into the outlet barb.
- Removable reservoir makes cleaning simple.
Cons
- No flow figures between zero lift and the 20 ft limit.
- The 3.3 ft cord needs an outlet very close by.
- Voltage is stated three different ways across the listing.
Alternatives worth comparing



Compared with and featured in
Final verdict
Buy the CDS320 to replace a tank pump at a furnace or air handler where the line climbs well below 20 ft and you want overflow protection wired in. If the climb is taller or you want maker curves, look at the alternatives above.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is the Aquastrong CDS320 a 1/38 HP or a 0.38 HP pump?
The title says 1/38 HP, which suits a small condensate motor. One spec row on the same listing reads 0.38 hp, which looks like the fraction typed as a decimal. Treat the motor as a fractional-horsepower unit and size it on lift and flow, not on that row.
Does the CDS320 need a separate check valve?
No. The listing places a check valve inside the barbed outlet, so water in the line cannot run back into the tank when the motor stops. Adding a second valve in the tubing only adds resistance.
Can it run on 230 V?
The title names 115V/230V and the brand's comparison chart says 100V~230V, but the spec row lists only 115 volts and the plug is a standard 3-prong type. Before using it on a 230 V circuit, ask Aquastrong to confirm in writing.
How does the safety switch shut off my furnace?
Two leads from a high-water sensor are wired into the equipment's low-voltage control loop. When water rises past the normal stop point and keeps climbing, the switch opens that loop and the appliance stops making condensate until the pump clears the tank.