Quick verdict
The 404 solves a different problem from a basement sump pump. It sits on the floor beside a laundry tub, bar sink or dehumidifier that lies below the drain line and lifts that gray water up to it. Its low height, gas-tight gasket and float that lifts out through its own small cover make it tidy to live with. It is not meant for groundwater, sewage, garbage disposals or water hotter than 140 °F.
Who it fits, and who should skip it
A good fit if
- A laundry tub or utility sink in the basement sits below the main drain.
- The space under a bar sink or beside a washer is too low for a taller basin.
- You want the float serviceable without breaking the plumbing apart.
Look elsewhere if
- You need to drain a sump pit fed by footing tile.
- A toilet or kitchen disposal must feed the unit; that calls for a sewage system.
Specifications
Motor
| Horsepower | 1/3 HP |
|---|---|
| Voltage | 115 V, single phase, 60 Hz |
| Amps | 5.2 A full load, 8 A locked rotor |
| Motor type | Oil-filled PSC, 3450 RPM, thermal overload, finned aluminum housing |
Figures: Liberty Pumps 404-Series system specifications 404_P1.
Performance
| Max flow | 38 GPM at 5 ft of total head |
|---|---|
| Max head | 21 ft shut-off head |
Figures: Liberty Pumps 404-Series system specifications 404_P1.
Switch
| Switch type | Wide-angle tilt float with piggyback plug, on a removable rod (QuickTree) |
|---|---|
| On / off levels | Not stated on the data sheet; tether length 2.75 in |
Figures: Liberty Pumps 404-Series system specifications 404_P1; Liberty Pumps Model 404 sales literature LLIT004600; Liberty Pumps installation manual 7212000J, automatic drain pumps 404 and 405.
Basin
| Discharge | 1-1/2 in female NPT (2 in on 404L) |
|---|---|
| Inlet and vent | 1-1/2 in female NPT each (2 in on 404L) |
| Basin | Polypropylene, 4.3 gallons, molded rubber gasket |
| Size | 11-1/8 in tall, 13-3/4 in major width |
| Weight | 13 lb on the sales sheet; the spec page lists 23 lb |
Figures: Liberty Pumps 404-Series system specifications 404_P1; Liberty Pumps Model 404 sales literature LLIT004600.
Pump
| Solids handling | 3/8 in, vortex engineered polymer impeller |
|---|---|
| Power cord | 10 ft, 3-wire grounded plug |
| Max liquid temperature | 104 °F continuous, 140 °F intermittent |
| Listings | SSPMA, cCSAus; 404CV listed to ASME A112.3.4 / CSA B45.9 |
| Warranty | 3-year limited |
Figures: Liberty Pumps 404-Series system specifications 404_P1; Liberty Pumps Model 404 sales literature LLIT004600.
Versions
Suffixes add a check valve, an alarm or a larger pipe size; the pump and basin are the same.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| 404, standard | 404 (retail item 3140788) | 1-1/2 in connections, no alarm, no check valve | View on Amazon |
| 404CV | 404CV | Adds a check valve that threads into the cover | Not linked |
| 404/A and 404CV/A | 404/A, 404CV/A | Factory-mounted alarm float with Liberty's standard alarm | Not linked |
| 404/A-EYE and 404CV/A-EYE | 404/A-EYE, 404CV/A-EYE | NightEye wireless alarm in place of the standard alarm | Not linked |
| 404L | 404L | 2 in inlet, discharge and vent | Not linked |
Figures: Liberty Pumps 404-Series system specifications 404_P1; Amazon listing B01NCBCFY2, Liberty 404.
Installation and setup
The 404 must be gravity-fed, so place it where the fixture drains downhill into it. Either the top port or the side port can serve as inlet, the other as vent. Liberty asks for a trap between fixture and basin, with a flange type preferred. A washing machine should empty into a laundry tray first, not straight into the unit.
On the outlet, fit a union just above the cover and a check valve right above that, unless you bought a CV model, whose valve threads directly into the cover. The vent must tie into the house vent; Liberty rules out air admittance valves and spring vents because the basin has to breathe both ways. Hand-tighten all plastic threads. Plug into a grounded 15-amp outlet with GFCI protection, never through an extension cord.
Switch and sizing notes
A tilt float inside the basin starts the pump as gray water collects and stops it as the level falls. Liberty mounts it beneath a separate sealed access cover on a stainless rod, so the whole float assembly lifts out for inspection while the pipes stay connected. The manual gives a tether length of 2.75 in but no on and off heights. Its piggyback plug lets you bypass a failed switch and run the pump by hand.
For sizing, the maker states 38 GPM at 5 ft and no flow at 21 ft. A drain line usually rises only to the ceiling joists, so most installs sit near the high-flow end of that range. Our laundry and sink pump guide explains how to estimate the lift, and the head calculator adds pipe friction.
Ownership and maintenance
Lint is the main enemy. Liberty's schedule is a monthly clean-out of the trap ahead of the unit and a quarterly check that the float moves freely. Keep paint thinner, grease and chemicals out of the drain, and never connect a disposal.
Alarm models add a high-water float; drill the 1/8 in air hole Liberty shows if the top port carries the vent, or trapped air can stop the alarm float rising. The system carries Liberty's three-year limited warranty.
Pros and cons
Pros
- Short basin fits under sinks and beside appliances.
- Float lifts out through its own cover, plumbing stays put.
- Gas-tight molded gasket rated for a 10 ft stack test.
- Alarm, wireless alarm and check valve versions available.
Cons
- Not for groundwater, sewage or disposals.
- Switch levels are not published.
- Maker sheets disagree on the unit's weight.
Alternatives worth comparing



Final verdict
For a basement laundry tub, utility sink or dehumidifier below the drain, the 404 is a neat, low and well-sealed answer that comes ready to plumb. Choose a CV or alarm version if you want those parts factory-fitted, and look elsewhere for sump or sewage duty.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Can a washing machine drain into the Liberty 404?
Liberty's manual says to drain a washing machine into a laundry tray sink and let the tray feed the 404, rather than piping the washer straight in. The tray absorbs the surge from the washer's own pump and catches lint before it reaches the basin and float.
Does the 404 need a vent?
Yes. One of the two ports must connect to the building vent, and Liberty forbids air admittance valves or spring-loaded vents. Air has to move freely in and out as the basin fills and empties, or the fixture drains slowly and the float misbehaves.
What do the CV and A-EYE suffixes mean?
CV models include a check valve meeting ASME A112.3.4 and CSA B45.9 that threads into the cover. A models add a factory-mounted alarm float with a standard alarm, and A-EYE models use the NightEye wireless alarm. The 404L has 2 in connections instead of 1-1/2 in.
How hot can the drain water be?
The 404 is rated for 104 °F in continuous duty and 140 °F intermittently. The manual warns that hotter water overheats the pump. Liberty's commercial 405 sibling takes water up to 180 °F if a dishwasher or similar source is involved.