Shallow well jet ยท Red Lion

Red Lion PWJET50 Shallow Well Jet Pump

The PWJET50 is Red Lion's basic 1/2 HP shallow well jet pump: cast iron, a preset 30/50 switch, and 7.4 GPM at 30 psi when water is 5 ft below it.

Model PWJET50 · part number 97080501 · Updated November 2026

Horsepower
1/2 HP
Voltage
115/230 V, set for 230 V at the factory
Max flow
9.8 GPM at 20 psi, 5 ft lift
Max head
145 ft (63 psi) at a 5 ft lift
Switch type
30/50 psi pressure switch, factory preset

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

This is a pump for light demand: a seasonal cottage, a camp or a garden tap fed from a sandpoint. Its 6.6 A motor is easy on small circuits, but its output is modest and it falls off steeply with lift, to 3.6 GPM at 30 psi from 25 ft. The warranty is one year, against three for Red Lion's premium jets.

Who it fits, and who should skip it

A good fit if

  • A cottage or cabin with a single bathroom.
  • A driven well point no deeper than 25 ft.
  • Circuits where a low-current 1/2 HP motor is welcome.

Look elsewhere if

  • A full-time family home with several fixtures running together.
  • Owners who want a long warranty term on the pump.

Specifications

Motor

Horsepower1/2 HP
Voltage115/230 V, set for 230 V at the factory
Amps6.6 A at 115 V, 3.3 A at 230 V
Motor designTEFC with automatic-reset thermal protector

Figures: Red Lion PWJET50 owner's manual 10000013802 Rev. 02; Red Lion Shallow Well Jet Pump PWJET50 product page.

Performance

Max flow9.8 GPM at 20 psi, 5 ft lift
Max head145 ft (63 psi) at a 5 ft lift
5 ft lift: 30 / 40 / 50 psi7.4 / 4 / 1.3 GPM
15 ft lift: 20 / 30 / 40 psi6.7 / 5.9 / 2.9 GPM; max 59 psi (137 ft)
25 ft lift: 30 / 40 psi3.6 / 2 GPM; max 56 psi (129 ft)
Suction lift limit25 ft including draw-down

Figures: Red Lion Shallow Well Jet Pump PWJET50 product page; Red Lion PWJET50 owner's manual 10000013802 Rev. 02.

Controls

Switch type30/50 psi pressure switch, factory preset
Tank precharge28 psi

Figures: Red Lion PWJET50 owner's manual 10000013802 Rev. 02; Red Lion Shallow Well Jet Pump PWJET50 product page.

Connections

Discharge1 in FNPT
Suction1-1/4 in FNPT

Figures: Red Lion PWJET50 owner's manual 10000013802 Rev. 02.

Build

ConstructionCast iron
Carton weight23 lb
Warranty1-year limited

Figures: Red Lion Shallow Well Jet Pump PWJET50 product page; Red Lion PWJET50 owner's manual 10000013802 Rev. 02.

Installation and setup

Red Lion's manual walks through two common sources. For a driven well, the point goes in no deeper than 25 ft, with galvanized rise pipe in sections of about 5 ft and a 1-1/4 in check valve at the top; if one point cannot keep up, the maker suggests several points joined together. For a drilled well, the foot valve hangs 4 ft above the bottom on 1-1/4 in pipe.

Set the pump indoors on a bolted, level base close to the well. Keep the suction side airtight, never fit a check valve between pump and tank, and add a relief valve sized for full flow at 75 psi. Well-point systems also need a restrictive valve at the tank. Plan the outlet piping so friction loss never exceeds 20 ft of head.

The motor ships on 230 V. A screwdriver slides the voltage indicator to 115 V if that is the supply, and the manual calls for a GFCI and copper conductors.

Switch and sizing notes

The 30/50 switch comes preset, and the tank's air should be set to 28 psi when empty. On a driven well that can be pumped down, Red Lion advises having an electrician swap in a low-pressure cut-off switch, which stops the motor when pressure collapses instead of letting it run dry. The switch settings guide explains the difference.

Size it honestly: from a 15 ft lift the pump gives 5.9 GPM at 30 psi and only 2.9 GPM at 40 psi, which covers one shower or one tap at a time. If the household is larger, the RJS-50-PREM has the same horsepower class but a stronger published curve.

Ownership and maintenance

Priming uses both a vent plug and a priming plug. Pour in about a quart of water for every 3 ft of suction line until it runs from the vent hole, close the vent, top up the casing, then start the pump. With an inline check valve this takes a few short runs; after eight failed tries, stop and hunt for a suction leak.

Drain the casing through its plugs before frost, keep the mounting bolts tight, and replace seals or the impeller when output fades. The motor's thermal protector resets itself, so a pump that stops and restarts on its own is overheating or overloaded and needs attention.

Pros and cons

Pros

  • Low current draw for a 1/2 HP motor.
  • Clear well-point and drilled-well instructions.
  • Preset 30/50 switch and dual voltage.
  • Totally enclosed fan-cooled motor.

Cons

  • Low flow at 40 psi and above.
  • Warranty runs one year only.
  • Steep fall in output near the 25 ft limit.

Alternatives worth comparing

Final verdict

The PWJET50 is a fair choice for a cottage or a light-duty well point where low current draw matters more than output. For a full-time home, spend more on a premium jet with a stronger curve and a longer warranty.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

How many fixtures can the PWJET50 supply?

Red Lion pitches it at cottages or homes with one bathroom. Its published flow at a 15 ft lift is 5.9 GPM at 30 psi and 2.9 GPM at 40 psi, which suits one fixture at a time rather than several running together.

Can it pump from a driven well point?

Yes. The manual covers driven points up to 25 ft deep with galvanized rise pipe and a check valve, and it recommends a low-pressure cut-off switch because a point can be pumped dry. A restrictive valve at the tank is also listed for point installs.

How long is the PWJET50 warranty?

Red Lion gives one year from the original purchase. Running the pump dry or pumping sand and other abrasives voids it, so prime it fully before switching on and keep a screen or foot valve on the suction end.

Why does the PWJET50 start and stop by itself?

If it cycles with no taps open, look for a leak or a tank that has lost its air charge. If the motor quits and restarts after a pause, the automatic thermal protector is tripping, which points to overheating, low voltage or an overload.