Quick verdict
A compact, quiet booster for a whole house or a cabin. Instead of adding a fixed boost, it speeds up and slows down to keep the pressure you choose, which gives steady showers as taps open and close. It can boost the mains or draw from a well or tank. It is a pressure booster, not a hot-water circulator, and its curve is published only as a graphic.
Who it fits, and who should skip it
A good fit if
- You want steady pressure at every tap, not just more of it.
- You need to draw from a shallow well or storage tank.
- Noise matters because the pump sits near living space.
Look elsewhere if
- The water is warmer than 113 °F.
- Local rules forbid boosting directly from the mains.
Specifications
Motor
| Voltage | 1 x 115 V, 60 Hz; NEMA 5-15P plug on a 6 ft cable |
|---|---|
| Power input | 560 W at 115 V; 5 to 5.7 A |
| Horsepower | Not stated by Grundfos (listed in watts) |
Figures: Grundfos SCALA2 installation and operating instructions 98880508.
Performance
| Max head | 45 m (147 ft) |
|---|---|
| Rated flow | 3 m³/h (from the type code) |
| Pressure setting | 22 to 80 psi in 7 psi steps; factory set 44 psi |
| Max suction lift | 8 m (26 ft); self-priming |
Figures: Grundfos SCALA2 installation and operating instructions 98880508.
Limits
| Max inlet pressure | 6 bar (87 psi) |
|---|---|
| Max system pressure | 10 bar (145 psi) |
| Max liquid temperature | 45 °C (113 °F) |
Figures: Grundfos SCALA2 installation and operating instructions 98880508.
Build
| Built-in tank precharge | 1.25 bar (18 psi) |
|---|---|
| Connections | NPT 1 in (R 1 in on other versions) |
| Noise | Under 47 dB(A) in a typical application |
| Weight | 10 kg (22 lb) |
| Product number | 98562818 (115 V version) |
Figures: Grundfos SCALA2 installation and operating instructions 98880508; Amazon listing B01K7RD1ZG.
Installation and setup
Mount the pump level, within 5° of horizontal, on a solid base or a vibration-damping pad, in a frost-free, ventilated spot where its vent holes cannot be flooded; Grundfos suggests a drip tray piped to a drain. Fittings and valves are not included. Fit isolating valves, and use the flexible hoses and pipe hangers Grundfos recommends to cut transmitted noise. Tighten the union nuts by hand, sealing the threads with tape.
Before starting, pour at least 1.7 litres of water into the priming port. Open a tap, plug in, let it run until the water is free of air, then open the highest outlet, ideally a shower, and set the pressure. On a well, a foot valve with strainer and an inlet filter protect it from sand.
Switch and sizing notes
There is no pressure switch. A built-in frequency converter varies the speed to hold the setpoint, adjustable from 22 to 80 psi in 7 psi steps, with 44 psi from the factory. The rise over inlet pressure must not exceed 51 psi, and the higher settings need positive inlet pressure from the mains. From a well, Grundfos caps the setpoint at 44 psi. If the pump cannot reach the target, a self-learning function lowers it.
For efficiency, set the built-in tank precharge to about 70% of the setpoint, for example 30 psi at the 44 psi default. The flow curve in the manual is a graphic, so check flow at your chosen pressure on that chart. See the booster guide for sizing to your fixtures.
Ownership and maintenance
The shaft seal is lubricated by the water, and Grundfos notes a slight seep of up to 10 ml a day during run-in, which normally evaporates. Keep the pump from freezing and drain it if the house is left unheated. If it runs for a few minutes after the taps close, the setpoint may be too high for the supply. Grundfos lists service kits, and the Grundfos Eye light on the panel shows faults.
Pros and cons
Pros
- Holds a constant pressure as demand changes.
- Self-priming, so it can draw from a well or tank.
- Quiet for a booster, under 47 dB(A) typically.
- Built-in tank and motor protection.
Cons
- Flow curve published only as a graphic.
- Water limited to 113 °F.
- Higher setpoints need mains inlet pressure.
Alternatives worth comparing



Compared with and featured in
Final verdict
Choose the SCALA2 3-45 for steady, quiet pressure from the mains, a well or a tank. Set the pressure sensibly for your supply, and read the maker's chart for flow at that setting.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
What pressure can the Grundfos SCALA2 deliver?
It can be set from 22 to 80 psi in 7 psi steps, and it leaves the factory at 44 psi. The rise above your inlet pressure must stay within 51 psi, and settings above 58 psi need positive inlet pressure.
Can the SCALA2 pull water from a well?
Yes. It is self-priming with a maximum suction lift of 26 ft, and the inlet pipe must sit at least 1.64 ft under water. Grundfos limits the setpoint to 44 psi when drawing from a well.
How much power does the SCALA2 3-45 use?
Grundfos lists 560 W and 5 to 5.7 A for the 115 V version, with 2 W in standby. The motor's speed falls when demand drops, so it uses less power at low flow than a fixed-speed pump.
What do the numbers 3-45 mean?
In Grundfos's type code, the 3 is the rated flow in cubic metres per hour and the 45 is the maximum head in metres, which equals 147 ft. The full product number for the 115 V version is 98562818.