Set the tank's air precharge 2 psi below the pump's cut-in pressure with the tank empty: 28 psi for a 30/50 switch, 38 psi for 40/60. Size the tank so the pump runs at least one minute per cycle. Amtrol's sizing table puts a 10 GPM pump of 3/4 hp or less on a 40/60 switch with a WX-250, which holds about 11.8 gallons of drawdown.
What a pressure tank does
A diaphragm well tank holds a cushion of air above a flexible membrane. When the pump runs, water fills the space below the membrane and squeezes the air, raising the pressure until the pressure switch turns the pump off. When you open a tap, the compressed air pushes water out, the pressure falls, and at the cut-in pressure the switch starts the pump again. Amtrol calls the water delivered between starts the drawdown.
The tank's whole purpose is to stretch those cycles. A larger drawdown means fewer pump starts, and Amtrol is direct about the payoff: fewer cycles mean longer tank and pump life and lower energy use. It recommends at least one minute of run time per cycle for pumps up to 3/4 hp and two minutes for larger pumps. A tank that is too small, or has lost its air, makes the pump short cycle, which is hard on the motor and on the switch contacts.
Setting the air pressure (precharge)
The air precharge must match the switch. Both Amtrol and Pentair use the same rule: set the precharge 2 psi below the cut-in pressure. Amtrol's own example is 38 psi for a 40/60 switch. New Well-X-Trol tanks ship at 38 psi, which suits 40/60 out of the box but must be lowered to 28 psi for a 30/50 switch.
Check and set it only with the tank empty of water and the system off: turn off the pump, open a tap until the pressure reads zero, then read the air valve with a tire gauge and add or release air. Amtrol attaches serious warnings to this step. Do not add air to a tank that has lost its precharge, shows exterior corrosion, or has started short cycling compared with when it was new, because loss of air can mean internal corrosion and repressurizing can make it burst. Amtrol says only licensed professionals should check, adjust or recharge tanks.
| Switch setting | Cut-in | Tank precharge |
|---|---|---|
| 20/40 | 20 psi | 18 psi |
| 30/50 | 30 psi | 28 psi |
| 40/60 | 40 psi | 38 psi |
Figures: Pentair instructions for adjusting well pump pressure switches U80-129; Amtrol Well-X-Trol installation and operation instructions 9015-868.
Drawdown by tank size
Tank volume and drawdown are not the same. A tank labeled 20 gallons gives only about 5 to 6 gallons of water between pump starts, and drawdown shrinks as the switch setting rises, because the air is already compressed further. Amtrol publishes drawdown for each Well-X-Trol model at three switch settings, shown below for the common sizes. The WX-202 and WX-203 are the two sizes most often found in homes.
When comparing other brands, compare drawdown at your switch setting, not the nominal gallons on the label.
| Model | Tank volume | 30/50 | 40/60 | 50/70 |
|---|---|---|---|---|
| WX-200 | 14.0 gal | 4.3 | 3.8 | 3.3 |
| WX-202 | 20.0 gal | 6.2 | 5.4 | 4.7 |
| WX-202XL | 26.0 gal | 8.0 | 7.0 | 6.1 |
| WX-203 | 32.0 gal | 9.9 | 8.6 | 7.6 |
| WX-250 | 44.0 gal | 13.6 | 11.8 | 10.4 |
| WX-251 | 62.0 gal | 19.2 | 16.6 | 14.6 |
Figures: Amtrol Well-X-Trol specification and sizing card MC7025.
Sizing from your pump's flow
Amtrol's quick sizing table starts from the pump's discharge rate and the switch setting, and applies the one-minute rule for pumps up to 3/4 hp or the two-minute rule above that. Read across from your pump's flow in gallons per minute. A 5 GPM pump of 3/4 hp or less on 40/60 needs a WX-202; at 10 GPM it needs a WX-250; above 3/4 hp, the two-minute rule roughly doubles the tank.
The pump's flow is on its curve at your pumping depth and pressure, not its maximum. For a shallow-well jet pump like the Wayne SWS50 or a deep-well submersible like the Red Lion RL12G05-3W2V, read the maker table at your water depth. When in doubt, size up: Amtrol's own advice is that a larger tank means fewer cycles.
| Pump flow | 30/50 psi | 40/60 psi | 50/70 psi |
|---|---|---|---|
| 5 GPM | WX-202 | WX-202 | WX-202XL |
| 7 GPM | WX-202XL | WX-203 | WX-203 |
| 10 GPM | WX-203 | WX-250 | WX-250 |
| 12 GPM | WX-250 | WX-251 | WX-251 |
| 15 GPM | WX-251 | WX-251 | WX-255 |
Figures: Amtrol Well-X-Trol specification and sizing card MC7025.
Pressure tank vs booster pump
A pressure tank does not raise your water pressure; it stores water at the pressure the switch allows and smooths delivery between pump starts. If the pressure itself is too low, the answers are a higher switch setting within the pump's ability, or a booster pump. Pentair warns that a switch should never be set to cut in below 20 psi or cut out above 60 psi on its jet pumps, and that cut-out must be at least 5 psi below the pump's dead-head pressure.
Booster pumps such as the Grundfos SCALA2 are a different tool, normally used on municipal supplies or after a storage tank; the booster pump guide explains when one fits.
Checks, relief valve and service life
Amtrol asks for a relief valve at the tank connection set to open at excessive pressure, 125 psig or more, sized to pass the pump's flow at that pressure, in case the switch fails and the pump keeps running. Its maximum working pressure for the line is 150 psig. Amtrol also wants a licensed professional to inspect the system yearly and more often as it ages, and sets a seven-year limited warranty on WX models.
Watch for signs of a failing tank: the pump starting every few seconds when a tap runs, the pressure gauge swinging quickly between cut-in and cut-out, or water from the air valve when you press it, which means the membrane has failed. Those are replacement signs, not recharge signs. The pressure switch guide covers the switch side of the system.
Common mistakes
- Checking the precharge with water pressure still in the system.
- Leaving the factory 38 psi precharge on a 30/50 switch.
- Adding air to an old tank that has lost its precharge.
- Sizing by nominal tank gallons instead of drawdown.
- Omitting the relief valve at the tank connection.
Products that fit

Amtrol WX-202 Well-X-Trol Pressure Tank
Vertical 20-gallon tank that gives 5.4 gallons of drawdown at 40/60.

Amtrol WX-203 Well-X-Trol Well Tank
Vertical 32-gallon tank that gives 8.6 gallons of drawdown at 40/60.

Square D 9013FSG2J24 40/60 PSI Pressure Switch
40/60 pressure switch matched to a 38 psi tank precharge.

Square D FSG2J21CP 30/50 PSI Pressure Switch
30/50 switch that needs the tank set to 28 psi.
Questions readers ask
What should the air pressure be in my well tank?
Two psi below the pump's cut-in pressure, measured with the tank empty of water and the pump off. That is 38 psi for a 40/60 switch and 28 psi for 30/50. Amtrol and Pentair both use this rule.
What size pressure tank do I need for a four-bedroom house?
Size from the pump, not the bedrooms. Amtrol's table starts with pump flow: a 10 GPM pump of 3/4 hp or less on a 40/60 switch calls for a WX-250, while a pump over 3/4 hp needs a tank sized for two minutes of run time.
How much water does a 20 gallon pressure tank hold?
Much less than 20 gallons usable. Amtrol's WX-202 gives 6.2 gallons of drawdown at 30/50, 5.4 at 40/60 and 4.7 at 50/70. The rest of the tank is the air cushion.
Is a bigger pressure tank better?
Within reason, yes. More drawdown means fewer pump starts, which Amtrol says extends tank and pump life and saves energy. The limits are floor space, weight and the cost of the tank.