Quick verdict
This is the standard replacement switch for a well system running a 40/60 band, and its double-pole contacts disconnect both hot legs of a 230 V pump circuit. If your well can run dry, the M4 version with a low-pressure cut-off is the safer choice.
Who it fits, and who should skip it
A good fit if
- Well systems set to start at 40 psi and stop at 60 psi.
- Single-phase pumps up to 2 hp on 230 V or 1.5 hp on 115 V.
- A like-for-like swap for a worn 9013FSG2 switch.
Look elsewhere if
- Wells that can be pumped dry, unless you choose the M4 version.
- Damp or outdoor spots without a rated enclosure, since it is NEMA 1.
Specifications
Setting
| Factory setting | 40/60 psi |
|---|---|
| Adjustable range, rising | 137.9 to 448.2 kPa |
| Differential | Adjustable, about 103.4 to 206.8 kPa |
| Listing description | 20-65 psi cut-out, 15-30 psi adjustable differential |
Figures: Telemecanique Sensors 9013FSG2J24 Pumptrol product data sheet; Amazon listing B000IKBNLM.
Electrical
| Contacts | 2 NC, snap action, DPST-DB |
|---|---|
| Single-phase motor rating | 1.5 hp at 115 V; 2 hp at 230 V |
| Short-circuit protection | 20 A cartridge fuse, type gG |
| Terminals | Screw clamp, up to 10 AWG |
Figures: Telemecanique Sensors 9013FSG2J24 Pumptrol product data sheet.
Connection
| Fluid connection | 1/4 in NPSF internal |
|---|---|
| Controlled fluid | Fresh water, 32 to 158 °F |
Figures: Telemecanique Sensors 9013FSG2J24 Pumptrol product data sheet.
Build
| Enclosure | NEMA 1, IP20 |
|---|---|
| Diaphragm | Nitrile (Buna-N) rubber |
| Electrical durability | 100000 cycles at under 10 cycles per minute |
| Standards | UL 508; NSF ANSI 61 Annex G |
Figures: Telemecanique Sensors 9013FSG2J24 Pumptrol product data sheet.
Versions
The 40/60 Pumptrol is sold in several packs and with an optional low-pressure cut-off.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| 9013FSG2J24, 40/60 psi | 9013FSG2J24 | Standard switch | View on Amazon |
| 9013FSG2J24M4, 40/60 psi | 9013FSG2J24M4 | Adds a low-pressure cut-off lever | View on Amazon |
| FSG2J24CP, 40/60 psi | FSG2J24CP | Retail pack of the same switch | View on Amazon |
Figures: Amazon listing B000IKBNLM; Amazon listing B000IJWSDA (9013FSG2J24M4); Amazon listing B01M3VYDYI (FSG2J24CP).
Installation and setup
Turn off the power and relieve the water pressure before removing an old switch. Clear the port of scale, since a blocked inlet makes a new switch chatter or fail to cut out. Thread the switch on, wire line and load to the marked terminals with the ground, and close the cover.
The datasheet allows any mounting position, but a short, straight connection to the tank tee gives the most stable reading. A switch mounted far from the tank, or behind a filter, sees pressure swings that make it chatter. Use copper wire sized for the motor and a fuse no larger than the rating given.
Compatibility
The switch threads onto a 1/4 in NPSF port, typically on the tank tee or pump body, and controls the pump through two normally closed contacts that break both hot legs. Check the motor: the datasheet rates it for single-phase pumps up to 1.5 hp at 115 V and 2 hp at 230 V. Larger motors need a contactor.
With a 40/60 setting, the pressure tank should hold 38 psi of air, 2 psi below cut-in. If you are moving from 30/50 to 40/60, read the switch settings guide first: some jet pumps lose much of their flow near 60 psi. For the 30/50 version of the same switch, see the FSG2J21CP.
Ownership and maintenance
The datasheet allows up to 10 cycles per minute and rates the contacts for 100000 electrical operations. Pitted contacts or a switch that buzzes usually mean worn points, short cycling from a waterlogged tank, or a clogged port; fix the cause before replacing the switch.
Check the pressure gauge against the switch now and then: if the pump starts or stops far from 40 and 60 psi, recheck the tank charge first, then adjust or replace the switch.
Pros and cons
Pros
- Breaks both hot legs with DPST contacts.
- Rated to 2 hp at 230 V single phase.
- Adjustable range and differential.
- M4 version available with low-pressure cut-off.
Cons
- NEMA 1 cover is for indoor use.
- Standard version has no dry-run protection.
- Datasheet range given in kPa, not psi.
Alternatives worth comparing



Final verdict
The 9013FSG2J24 is the dependable choice for a 40/60 well system on a single-phase pump up to 2 hp. Pick the M4 version where the well can run dry, and set the tank to 38 psi.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is the 9013FSG2J24 a Square D or Telemecanique part?
Both names refer to the same Schneider Electric Pumptrol 9013FS line. The current datasheet carries the Telemecanique Sensors name, while many retailers and installers still call it a Square D switch.
What does the M4 suffix add?
The 9013FSG2J24M4 version adds a low-pressure cut-off. If pressure collapses, such as when the well runs dry, it opens the circuit and must be reset by hand, which protects the pump from running without water.
Can I adjust it to 30/50?
The range is adjustable, but a dedicated 30/50 switch such as the FSG2J21 starts closer to that band. Any adjustment should follow the maker's instructions, and the tank precharge must change to 2 psi below the new cut-in.
What size pump can it control?
The datasheet rates it for single-phase motors up to 1.5 hp at 115 V and 2 hp at 230 V, and three-phase motors up to 3 hp at 230 V. Use a contactor for anything larger.