Quick verdict
This is one of the most common household well tank sizes, and Amtrol's sizing table shows why: it matches pumps of roughly 7 to 10 GPM up to 3/4 hp. Its extra drawdown over the 20 gal WX-202 means fewer pump starts. It needs headroom, though, at nearly four feet tall.
Who it fits, and who should skip it
A good fit if
- Pumps of about 7 GPM on 40/60 or 50/70, or 10 GPM on 30/50.
- Households that want fewer pump starts per day.
- Rooms with at least 47 in of clear height.
Look elsewhere if
- Pumps over 3/4 hp, which Amtrol pairs with larger tanks.
- Low crawl spaces or outdoor, freezing locations.
Specifications
Capacity
| Tank volume | 32.0 gal |
|---|---|
| Drawdown at 30/50 psig | 9.9 gal |
| Drawdown at 40/60 psig | 8.6 gal |
| Drawdown at 50/70 psig | 7.6 gal |
| Maximum acceptance factor | 0.35 |
Figures: Amtrol Well-X-Trol specification card MC7025.
Pressure
| Factory precharge | 38 psig |
|---|---|
| Maximum working pressure | 150 psig |
Figures: Amtrol Well-X-Trol specification card MC7025; Amtrol Well-X-Trol installation and operation instructions 9015-868.
Size
| Diameter x height | 15 x 47 in |
|---|---|
| System connection | 1 in NPTF stainless steel |
| Shipping weight | 47 lb |
Figures: Amtrol Well-X-Trol specification card MC7025.
Use
| Mounting | Vertical only |
|---|---|
| Temperature range | Above freezing, not above 130°F |
| Warranty | Seven-year limited |
Figures: Amtrol Well-X-Trol installation and operation instructions 9015-868; Amtrol warranty MC10253.
Installation and setup
Place the tank upright on a level floor, out of frost and away from heat over 130°F, with a floor drain nearby if a leak could cause damage. Check and set the precharge with a tire gauge before any water goes in, then plumb the 1 in connection to the tank tee with the switch, gauge and relief valve.
Some retail listings print this tank's size as 1 x 15 x 47 in; Amtrol gives 15 in diameter by 47 in height.
Compatibility
Any well pump and pressure switch will work with the WX-203 once its precharge is set 2 psig below cut-in: 28 psig for 30/50, the factory 38 psig for 40/60, or 48 psig for 50/70. The 1 in female stainless connection fits a standard tank tee.
Amtrol's quick sizing table, built on at least one minute of run time for pumps up to 3/4 hp, lists the WX-203 for about 7 GPM at 40/60 or 50/70 and about 10 GPM at 30/50. Pumps over 3/4 hp are sized for two minutes of run time and jump to larger models. For a smaller pump, the WX-202 is enough. Our tank sizing guide walks through the arithmetic.
Ownership and maintenance
Once a year, switch off the pump, drain the system and recheck the air charge. If water appears at the air valve, the diaphragm has failed and Amtrol says not to recharge it; replace the tank.
The warranty is seven years, limited. Amtrol states that Well-X-Trol tanks bought from online sellers are ineligible for its manufacturer support, so buy from a dealer if cover matters.
Pros and cons
Pros
- 9.9 gal drawdown at 30/50 for longer pump runs.
- Sized by Amtrol for common 7 to 10 GPM pumps.
- Stainless steel water connection.
- Seven-year limited warranty via dealers.
Cons
- Stands 47 in tall.
- Maker support excluded for online purchases.
- Must be installed upright and indoors.
Alternatives worth comparing



Compared with and featured in
Final verdict
The WX-203 is the Well-X-Trol to choose for a typical 3/4 hp household pump of around 7 to 10 GPM. Make sure you have the height, set the air to suit your switch and buy from a dealer to keep the warranty.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How many gallons does a WX-203 deliver between pump cycles?
Amtrol lists drawdown of 9.9 gal at 30/50 psig, 8.6 gal at 40/60 and 7.6 gal at 50/70. The 32 gal figure is the total tank volume, most of which holds the compressed air charge.
What size pump suits the WX-203?
Amtrol's quick sizing table assigns it to pumps up to 3/4 hp of about 7 GPM on 40/60 or 50/70 settings, or about 10 GPM on 30/50, for at least one minute of run time.
What precharge should I set?
Two psig below the switch cut-in. The tank ships at 38 psig, right for 40/60. For a 30/50 switch set 28 psig, measured with the pump off and the tank drained.
How tall is the WX-203?
Amtrol gives 47 in high and 15 in in diameter, with a shipping weight of 47 lb. Some retail listings show garbled dimensions, so plan the space from the maker's figures.