Quick verdict
The WX-202 is a mid-size tank for a small pump. Amtrol's own quick sizing table pairs it with a pump of about 5 GPM and up to 3/4 hp on a 30/50 or 40/60 switch. Bigger pumps empty it quickly and start too often, so check your pump's flow before choosing this size.
Who it fits, and who should skip it
A good fit if
- Pumps around 5 GPM, up to 3/4 hp, on 30/50 or 40/60 settings.
- Basements or pump rooms with about 15 in of floor space.
- Replacing a waterlogged tank of similar size.
Look elsewhere if
- Pumps over 3/4 hp, which Amtrol sizes for larger tanks.
- Unheated spaces that freeze or rooms above 130°F.
Specifications
Capacity
| Tank volume | 20.0 gal |
|---|---|
| Drawdown at 30/50 psig | 6.2 gal |
| Drawdown at 40/60 psig | 5.4 gal |
| Drawdown at 50/70 psig | 4.7 gal |
| Maximum acceptance factor | 0.57 |
Figures: Amtrol Well-X-Trol specification card MC7025.
Pressure
| Factory precharge | 38 psig |
|---|---|
| Maximum working pressure | 150 psig |
Figures: Amtrol Well-X-Trol specification card MC7025; Amtrol Well-X-Trol installation and operation instructions 9015-868.
Size
| Diameter x height | 15 x 32 in |
|---|---|
| System connection | 1 in NPTF, stainless steel |
| Shipping weight | 32 lb |
Figures: Amtrol Well-X-Trol specification card MC7025.
Use
| Mounting | Vertical stand; mount vertically only |
|---|---|
| Temperature limit | Do not freeze; do not exceed 130°F |
| Warranty | Seven-year limited (Well-X-Trol WX) |
Figures: Amtrol Well-X-Trol installation and operation instructions 9015-868; Amtrol warranty MC10253.
Installation and setup
Stand the tank upright on a level floor in a space that never freezes and never tops 130°F. Amtrol requires vertical mounting only, and asks for a drain near the tank if a leak could cause damage.
Before filling, check the precharge with a tire gauge at the air valve, with the system empty, and adjust it to 2 psig below the switch cut-in. Then connect the 1 in fitting to the tank tee along with the switch, gauge and relief valve.
Compatibility
The WX-202 works with any well pump and pressure switch, as long as the precharge matches the switch. Amtrol's rule is 2 psig below cut-in: 28 psig for a 30/50 switch, or the factory 38 psig for 40/60. Its 1 in female thread suits a standard tank tee.
For sizing, Amtrol's quick table assumes one minute of run time for pumps up to 3/4 hp. On that basis the WX-202 matches a pump of about 5 GPM on 30/50 or 40/60. A 7 GPM pump on 40/60 steps up to the WX-203. The tank sizing guide explains drawdown and run time in more detail.
Ownership and maintenance
Check the air charge once a year with the pump off and the water drained. Amtrol warns not to add air to a tank that shows signs of a failed diaphragm, such as water at the air valve: replace it instead. Precharge changes should be made at room temperature.
The Well-X-Trol carries a seven-year limited warranty, but Amtrol states that tanks bought from online sellers are not eligible for its manufacturer support; it sells through wholesale distributors and local dealers.
Pros and cons
Pros
- Published drawdown at three switch settings.
- Stainless steel water connection.
- Seven-year limited warranty through dealers.
- Amtrol sizing table makes selection simple.
Cons
- Too small for pumps over about 5 GPM.
- Online purchases lose maker support, per Amtrol.
- Must stay indoors and upright.
Alternatives worth comparing



Compared with and featured in
Final verdict
The WX-202 is the right Well-X-Trol for a small pump of around 5 GPM. Set the precharge to suit your switch, keep it upright and frost-free, and buy through a dealer if the warranty matters to you.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How much water does the WX-202 hold between pump starts?
Amtrol lists drawdown of 6.2 gal at 30/50 psig, 5.4 gal at 40/60 and 4.7 gal at 50/70. Drawdown is the water delivered between the pump stopping and starting again, not the 20 gal tank volume.
What precharge should the WX-202 have?
It leaves the factory at 38 psig, which suits a 40/60 switch. For a 30/50 switch, release air to 28 psig. Always measure with the tank empty of water and the pump off.
Is the WX-202 big enough for my pump?
Amtrol's quick sizing table assigns it to pumps of about 5 GPM and up to 3/4 hp on 30/50 or 40/60 settings. Larger pumps need a bigger tank to keep run time near one minute or more.
Does buying online affect the warranty?
Amtrol states that it does not sell Well-X-Trol tanks online and that items bought from e-commerce sources are not eligible for manufacturer support. Buying from a local dealer keeps the seven-year limited warranty intact.