Well pressure switch ยท Square D by Schneider Electric

Square D FSG2J21CP 30/50 PSI Pressure Switch

The FSG2J21CP is the retail pack of Square D's 9013FSG2J21 Pumptrol, the 30/50 psi switch found on many jet and submersible well systems. Schneider rates the family for single-phase pumps up to 2 hp at 230 V.

Model FSG2J21CP · part number FSG2J21CP · Updated November 2026

Factory setting
30/50 psi
Contacts
DPST, 2 poles; open on rising pressure
Single-phase motor rating
1.5 hp at 115 V; 2 hp at 230 V
Fluid connection
1/4 in NPSF internal

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

This is the default replacement switch for a 30/50 well system, the band most shallow and convertible jet pumps ship with. It is simple, rated for common pump sizes and widely stocked. The datasheet saved here is for the M4 version with a low-pressure cut-off, so check which one you are buying.

Who it fits, and who should skip it

A good fit if

  • Jet or submersible systems set to 30 psi on and 50 psi off.
  • Single-phase pumps up to 2 hp at 230 V.
  • Replacing a worn FSG2 switch of the same band.

Look elsewhere if

  • Systems that need a 40/60 band; use the FSG2J24 instead.
  • Outdoor mounting without a weather-rated enclosure.

Specifications

Setting

Factory setting30/50 psi
Pressure setting range206.84 to 344.74 kPa
Adjustable range, rising137.9 to 448.2 kPa
Range on falling pressure68.95 to 310.26 kPa

Figures: Amazon listing B00CONESDG (FSG2J21CP); Square D Pumptrol 9013FSG2J21M4 product data sheet.

Electrical

ContactsDPST, 2 poles; open on rising pressure
Single-phase motor rating1.5 hp at 115 V; 2 hp at 230 V

Figures: Square D Pumptrol 9013FSG2J21M4 product data sheet; Amazon listing B00CONESDG (FSG2J21CP).

Connection

Fluid connection1/4 in NPSF internal

Figures: Square D Pumptrol 9013FSG2J21M4 product data sheet.

Build

Maximum pressure220 psig
DiaphragmNitrile (Buna-N)
EnclosureNEMA 1, for indoor use
Weight0.51 kg
M4 optionLow-pressure cut-off roughly 10 psig below cut-in

Figures: Square D Pumptrol 9013FSG2J21M4 product data sheet.

Versions

The 30/50 Pumptrol is sold as a retail pack and as the plain 9013FSG2J21; an M4 version adds low-pressure cut-off.

VersionPart numberWhat differsListing
FSG2J21CP, 30/50 psi retail packFSG2J21CPStandard 30/50 switchView on Amazon
9013FSG2J21, 30/50 psi9013FSG2J21Same switch, standard part numberView on Amazon
9013FSG2J21M4, 30/50 psi9013FSG2J21M4Adds low-pressure cut-offNot linked

Figures: Amazon listing B00CONESDG (FSG2J21CP); Amazon listing B00TPYDHKC (9013FSG2J21); Square D Pumptrol 9013FSG2J21M4 product data sheet.

Installation and setup

Switch off the pump circuit and open a tap to drop the pressure to zero before removing the old switch. Clean any scale from the tank tee port, thread on the new switch with sealant on the threads, and wire line and load terminals as marked, with the ground bonded.

Mount it close to the tank. A long run of pipe, or a filter between pump and switch, causes pressure swings that make the contacts chatter and burn. Close the cover fully: the enclosure is NEMA 1, meant for dry indoor spaces.

Compatibility

Most jet pumps sold for shallow and convertible wells ship with a 30/50 switch, and many submersible systems use the same band. The FSG2J21 threads onto a 1/4 in NPSF port and switches both hot legs through its double-pole contacts. Schneider's ratings cover single-phase motors up to 1.5 hp on 115 V and 2 hp on 230 V; bigger pumps need a contactor.

Set the tank to 28 psi of air, 2 psi below the 30 psi cut-in. For systems that need more pressure, the 9013FSG2J24 is the 40/60 version. The switch settings guide explains the choice.

Ownership and maintenance

Contacts wear with every start, so short cycling from a waterlogged tank shortens switch life quickly. If the pump starts more often than it should, check the tank charge before suspecting the switch.

If the well can run dry, consider the M4 version. Its lever-reset cut-off opens the circuit when pressure falls roughly 10 psig below cut-in, stopping the pump before it overheats.

Pros and cons

Pros

  • Matches the most common jet pump band.
  • DPST contacts break both hot legs.
  • Rated for single-phase pumps to 2 hp.
  • Available with a low-pressure cut-off.

Cons

  • Indoor NEMA 1 enclosure only.
  • Standard version gives no dry-run protection.
  • Saved datasheet covers the M4 variant.

Alternatives worth comparing

Final verdict

The FSG2J21CP is the straightforward pick for any 30/50 well system on a single-phase pump up to 2 hp. Choose the M4 version where the well can run dry, and set the tank to 28 psi.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

What is the difference between FSG2J21CP and 9013FSG2J21?

The CP suffix marks a retail pack of the same Square D Pumptrol 30/50 switch. Both are the 9013FSG2J21 design. The M4 version is different: it adds a low-pressure cut-off lever.

How does the M4 low-pressure cut-off work?

On the 9013FSG2J21M4, the cut-off operates roughly 10 psig below cut-in. If pressure collapses, for example because the well ran dry, it shuts the pump off and you reset it by hand once the cause is fixed.

What tank precharge goes with a 30/50 switch?

Set the empty tank to 28 psi, 2 psi below the 30 psi cut-in. Too much air makes the pump start before the tank has delivered its full drawdown; too little lets the tank waterlog.

One listing says IP54. Is it weatherproof?