4 in deep well submersible · Red Lion

Red Lion RL12G05-3W2V Deep Well Submersible Pump

The RL12G05-3W2V is a 1/2 HP, 3-wire, 230 V submersible for 4 in and larger drilled wells. Red Lion rates it at 12 GPM with a shut-off head of 212 ft, and the control box comes in the carton.

Model RL12G05-3W2V · part number 14942405 · Updated November 2026

Horsepower
1/2 HP
Voltage
230 V single phase
Max flow
12 GPM rated flow
Max head
212 ft (64.6 m) shut-off
Discharge
1-1/4 in FNPT, thermoplastic

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

This is a modest pump for a shallow-to-moderate drilled well: water that sits within roughly a hundred feet of the surface, feeding a typical house. The 3-wire layout puts the start components in a box above ground, which makes a failed capacitor a bench job rather than a pull. Its 212 ft shut-off head leaves no room for deep settings or long uphill runs.

Who it fits, and who should skip it

A good fit if

  • A 4 in or larger drilled well with a moderate pumping level.
  • Replacing an existing 1/2 HP 3-wire pump on 230 V wiring.
  • Owners who want start parts in a box they can reach.

Look elsewhere if

  • Deep settings where total head approaches the 212 ft shut-off.
  • Houses with only a 115 V supply at the well.

Specifications

Motor

Horsepower1/2 HP
Voltage230 V single phase
Wiring3-wire; control box included
Amps6 A

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page.

Performance

Max flow12 GPM rated flow
Max head212 ft (64.6 m) shut-off
Performance curvePublished in the spec sheet; flattened in text, not quoted here

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page; Red Lion 4 in submersible well pumps RL series spec sheet.

Application

Well size4 in diameter and larger drilled wells
SettingAt least 5 ft above the well bottom and above the screen

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.

Build

Discharge1-1/4 in FNPT, thermoplastic
Pump shellStainless steel; thermoplastic motor bracket
Built-in partsSuction screen and check valve
Carton38 in long, 28 lb
Switch typeNone on the pump; uses a separate pressure switch
Warranty3-year limited

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in submersible well pumps RL series spec sheet.

Versions

Red Lion's model code reads gallons, horsepower, wires and voltage. These 1/2 HP RL pumps share the 12 GPM hydraulic end.

VersionPart numberWhat differsListing
RL12G05-3W2V, 3-wire, 230 V149424056 A; control box includedView on Amazon
RL12G05-2W2V, 2-wire, 230 V149424026 A; no control box neededNot linked
RL12G05-2W1V, 2-wire, 115 V1494240112 A; no control box neededNot linked

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page.

Installation and setup

Start with the driller's log: the setting depends on the static level plus draw-down at your pumping rate. Red Lion asks for the pump to hang at least 5 ft off the bottom and above the screen or casing perforations, unless water is guaranteed to flow past the motor.

Hang it on schedule 40 galvanized pipe (or plastic rated for the depth), with a steel safety cable of 3/16 to 1/4 in. A torque arrestor goes just above the pump, the cable is taped to the drop pipe every 10 ft, and an extra positive-sealing check valve sits in the line within 25 ft of the pump. Swing check valves are not allowed.

Before setting the seal, run the well clear through a partly open gate valve; if the water is still dirty after half an hour, stop and correct the problem.

Switch and sizing notes

The pump has no switch of its own. A separate pressure switch near the tank switches power to the control box, which in turn starts the motor. If the switch contacts are too small for the motor, Red Lion calls for a magnetic contactor. The pressure switch guide covers cut-in and cut-out choices.

Total head is the pumping level, plus the height to the tank, plus the tank pressure you want expressed in feet, plus pipe friction. Keep that well under 212 ft. The 1/2 HP size loses flow quickly as head rises, so a pumping level near the bottom of this range calls for the 3/4 HP RL12G07. The deep well picks compare other options.

Ownership and maintenance

The control box must be mounted out of rain and snow and away from temperatures below 14 °F. Red Lion's troubleshooting chart traces frequent cycling to plumbing leaks, a switch set too high, a waterlogged tank or a tank that is simply too small; check those before blaming the pump.

The internal check valve can be unscrewed for cleaning with a T-handle wrench; it has a left-hand thread and goes back at 15 inch-pounds. Warranty cover is three years, and it is void if anyone other than an authorized reseller opens the motor.

Pros and cons

Pros

  • Control box ships with the pump.
  • Start parts reachable above ground.
  • Built-in screen and check valve.
  • Three-year warranty from the maker.

Cons

  • Only 212 ft of shut-off head.
  • Needs 230 V and a fourth conductor.
  • Extra box to mount and protect.

Alternatives worth comparing

Final verdict

Choose the RL12G05-3W2V for a moderate-depth 4 in well on 230 V, especially when you value a control box you can service without pulling the pump. For deeper water, the 3/4 HP model is the safer buy.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

What does 3W2V mean in RL12G05-3W2V?

Red Lion's code reads 12 gallon class, 05 for 1/2 HP, three motor wires, and voltage code two for 230 V. A 3-wire pump has its start capacitor and relay in a separate control box above ground, which this model includes.

How deep can the RL12G05-3W2V pump from?

Its shut-off head is 212 ft, the point where flow stops. Real settings must be shallower, because pressure at the tank and pipe friction use up part of that head. Red Lion describes the RL series for drilled wells to depths of 250 ft across all sizes.

Does it need a separate check valve?

It has a built-in one, but Red Lion also asks for an in-line positive-sealing check valve within 25 ft of the pump and below the draw-down level, and more every 200 ft on deep settings. Swing-type valves must not be used.

Why do retail listings show different head figures?

Some retailer pages list a maximum head that differs from Red Lion's sheet. The maker's specification and owner's manual both give 212 ft of shut-off head for this model, so size from that figure.