Quick verdict
The 3/4 HP size is the common choice for a household well of middling depth. As a 2-wire pump it runs straight from the pressure switch with no box on the wall, so installation is simpler and there is less to fail above ground. If a start component ever does fail, though, it sits inside the motor down the well.
Who it fits, and who should skip it
A good fit if
- Drilled wells of 4 in or wider with a pumping level in the low hundreds of feet.
- Replacing a 3/4 HP 2-wire pump on an existing two-conductor-plus-ground drop cable.
- Owners who want no control box to mount.
Look elsewhere if
- Total head near 333 ft, where flow falls away.
- Sites that have no 230 V supply at the well.
Specifications
Motor
| Horsepower | 3/4 HP |
|---|---|
| Voltage | 230 V single phase |
| Wiring | 2-wire plus ground; no control box |
| Amps | 8 A |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page; Red Lion 4 in submersible well pumps RL series spec sheet.
Performance
| Max flow | 12 GPM rated flow |
|---|---|
| Max head | 333 ft (101.5 m) shut-off |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page.
Application
| Well size | 4 in and larger drilled wells |
|---|---|
| Minimum setting | 5 ft above the well bottom |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.
Build
| Discharge | 1-1/4 in FNPT, thermoplastic |
|---|---|
| Shell and bracket | Stainless steel shell, thermoplastic motor bracket |
| Intake | Built-in suction screen and check valve |
| Carton | 34.5 in long, 29 lb |
| Switch type | External pressure switch (not supplied) |
| Warranty | 3-year limited |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in submersible well pumps RL series spec sheet.
Versions
The 3/4 HP RL pump comes as a 2-wire or a 3-wire motor; both share the 12 GPM pump end and 333 ft shut-off.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| RL12G07-2W2V, 2-wire, 230 V | 14942403 | 8 A; runs directly from the pressure switch | View on Amazon |
| RL12G07-3W2V, 3-wire, 230 V | 14942406 | 8 A; control box included | Not linked |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.
Installation and setup
Read the well record before choosing a depth. The pump must stay fully submerged at full draw-down, at least 5 ft above the bottom, and above the screen unless water is known to pass the motor for cooling. Deeper is not better: every extra foot adds head.
Assemble on the surface: lead wires tucked under the guard, safety cable attached, drop pipe sealed, torque arrestor just above the pump. Tape the cable to the pipe every 10 ft, leaving slack on plastic pipe because it stretches. Before lowering, check continuity and insulation with an ohmmeter and a megger, which catches a nicked lead while it is still easy to fix.
Add positive-sealing check valves, one within 25 ft of the pump, and on settings over 200 ft one at each 200 ft interval. After lowering, run a well test through a gate valve until the water clears.
Switch and sizing notes
With a 2-wire motor, the pressure switch feeds the two hot conductors straight to the pump through a fused disconnect, and the motor's green lead goes to ground. A GFCI is required by the manual. Use a contactor if the switch contacts are not rated for the motor. Our switch settings guide covers the usual pressure bands.
For sizing, add the pumping level, the rise to the tank, the cut-out pressure in feet and friction in the drop and service pipe. That sum should sit comfortably below 333 ft, since flow is rated at 12 GPM only at moderate head. Also confirm the well can supply what the pump draws: Red Lion's fix for a low-yield well is a smaller pump. See the deep well pump picks for other sizes.
Ownership and maintenance
A healthy submersible needs little routine work, so watch the system around it. Red Lion lists rapid cycling causes as a leak between switch and tank, a switch set too high, a waterlogged or undersized tank, or a switch mounted too far from the tank. Reduced output points to a clogged intake screen, low voltage, a weak well or a worn pump.
The three-year warranty is handled through an authorized reseller, and opening the motor yourself voids it.
Pros and cons
Pros
- No control box to mount or protect.
- 333 ft of shut-off head for a 3/4 HP pump.
- Built-in screen and check valve.
- Simple wiring: two conductors plus a ground.
Cons
- Start parts sit inside the motor down the well.
- Needs a 230 V supply.
- Flow falls well below rating at high head.
Alternatives worth comparing



Compared with and featured in
Final verdict
The RL12G07-2W2V suits a typical household drilled well of moderate depth on 230 V, with the simplest wiring of the RL range. Choose the 3-wire version if you would rather keep start components where you can reach them.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is the RL12G07-2W2V a 2-wire or 3-wire pump?
It is 2-wire: two power conductors plus a ground, with the start parts built into the motor, so no control box is needed. Red Lion sells the same 3/4 HP pump as the RL12G07-3W2V, which is 3-wire and ships with a control box.
How deep a well can it serve?
Its shut-off head is 333 ft, where flow stops. A working setting has to leave room for tank pressure and pipe friction, so the practical pumping level is well below that. Red Lion describes the RL series for drilled wells to 250 ft.
Why does a retailer list a different maximum head?
At least one retail page quotes a lower maximum head for this model. Red Lion's manual and product page both give 333 ft of shut-off head, so the maker's figure is the one to size with.
What if the pump runs but delivers little water?
Red Lion's chart lists a clogged intake screen, a well that yields less than the pump draws, low voltage at the motor or a worn pump. Check voltage at the switch and the well's draw-down before pulling anything.