Tank condensate pump ยท Aquastrong

Aquastrong CDS125STU Condensate Pump with Tubing

The Aquastrong CDS125STU is a 115 V tank condensate pump sold with drain tubing, listed for 70 GPH and a 16 ft vertical lift, with an overflow switch on two leads for the furnace or air conditioner.

Model CDS125STU · part number CDS125STU · Updated November 2026

Max flow
70 GPH
Max head
16 ft vertical lift
Voltage
115 V
Switch type
Automatic float switch plus high-level safety switch
Discharge
2/5 in OD barbed outlet with check valve; fits 1/4 in to 3/8 in tubing

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

This is the short-climb member of Aquastrong's tank range, and the one that arrives with tubing, which saves a trip for a first install on a furnace, air handler, dehumidifier or ice maker. Its 16 ft rating is the lowest of the family, so it suits a pump that only has to lift the water up to a nearby joist and across to a drain.

Who it fits, and who should skip it

A good fit if

  • The tubing only climbs to the basement ceiling before running to a drain or sink.
  • You want drain tubing included rather than bought separately.
  • An ice maker or dehumidifier needs a small pump with a shut-off contact.

Look elsewhere if

  • The rise is anywhere near 16 ft or more.
  • Your circuit is not 115 V; this model is listed for 115 V only.

Specifications

Performance

Max flow70 GPH
Max head16 ft vertical lift
Flow at other heightsNot stated in the listing

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Motor

Voltage115 V
HorsepowerNot stated in the listing

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Switch

Switch typeAutomatic float switch plus high-level safety switch
On / off levelsStarts at 1.63 in, stops at 0.9 in
Safety switch leadsTwo lead wires that cut the appliance's power on high water

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Build

ReservoirRemovable, 1/2 gallon
InletsFive 1 in inlet ports
Discharge2/5 in OD barbed outlet with check valve; fits 1/4 in to 3/8 in tubing
Tubing included19.7 ft per title and style row (brand chart says 10 ft)
Power cord3.3 ft, 3-prong plug
Dimensions11.2 in L x 5.5 in W x 6.7 in H
ConstructionThermoplastic (polypropylene) body, vertical centrifugal pump

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Ownership

Cleaning intervalReservoir, float and filter every six months
WarrantyTwo-year warranty (listing text)

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Versions

The brand chart shows this 70 GPH pump with and without tubing; only the kit with tubing has a saved product page.

VersionPart numberWhat differsListing
CDS125STU with tubing, grayCDS125STU115 V tank pump plus drain tubing, 3.3 ft cordView on Amazon
70 GPH pump without tubingNot stated in the listingSame 70 GPH, 16 ft pump shown in the brand chart without tubingNot linked

Figures: Amazon listing B0CPJ15BLL, Aquastrong CDS125STU.

Installation and setup

Pick a level spot on the floor or a wall bracket within reach of the 3.3 ft cord. The listing asks for vertical mounting, so shim the reservoir if the slab slopes toward a floor drain. Run each appliance drain into one of the five 1 in inlets and cap the spares.

Push the supplied tubing over the 2/5 in OD barb and secure it with a clamp or tie. Lift it straight to its highest point, then slope it down toward the sink, standpipe or floor drain. Because the pump stops at only 16 ft, avoid long horizontal loops at ceiling height, which add friction the listing gives no allowance for. Cut the coil to length rather than leaving the extra tubing coiled behind the furnace.

Wire the two safety leads into the low-voltage control circuit of the air handler or furnace so a full tank stops the equipment. For a dehumidifier or ice maker, use an alarm if the appliance has no terminal for a shut-off contact.

Switch and sizing notes

This pump starts a little earlier and stops lower than Aquastrong's 85 GPH tank model: the float switch turns it on at 1.63 in and off at 0.9 in. That smaller band means shorter, more frequent runs. A separate high-level sensor trips the safety leads only if water keeps rising after the start point.

Size it by height. Measure from the pump outlet to the highest point the tubing reaches. The listing gives 70 GPH at the low end and 16 ft at the top, with nothing between, so leave a generous margin under that ceiling. A basement furnace draining up one wall and along the joists is a sensible job; a pump in a crawl space pushing up to an attic drain is not.

Ownership and maintenance

Aquastrong asks for the reservoir, float and filter to be cleaned every six months. On a high-efficiency furnace, acidic condensate and algae build up on the float stem and inside the basket, and a float that hangs up leaves the pump running dry or not at all.

Unplug, lift off the reservoir, rinse it, and wipe the float until it slides freely. Before refitting, check that the check valve in the barb closes; water that drains back from the tubing makes the pump cycle needlessly. The listing mentions a two-year warranty, so keep the order details.

Pros and cons

Pros

  • Drain tubing comes in the box.
  • Overflow leads protect the floor and the furnace.
  • Five inlet ports for several appliances.
  • Check valve built into the outlet.

Cons

  • Lowest lift of Aquastrong's tank pumps at 16 ft.
  • Tubing length is stated two different ways.
  • No flow-versus-height figures are published.

Alternatives worth comparing

Final verdict

Choose the CDS125STU for a simple furnace or dehumidifier drain with a modest climb, when having tubing in the box is handy. If the line must rise more than about two storeys of basement wall, move up to a pump rated for 20 ft or more.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

How much tubing comes with the Aquastrong CDS125STU?

The title and style row both say 19.7 ft of tubing. The brand's comparison chart, printed further down the same listing, says 10 ft of vinyl tubing for the pump-and-tube version. Measure your run and expect the shorter figure until the box is open.

Can the CDS125STU drain an ice maker?

The listing names ice makers among its uses, along with furnaces, air conditioners, dehumidifiers and condensing boilers. Check that the ice maker's drain sits above the pump's inlets, so water can fall into the reservoir.

Why does it run so often?

The float starts the motor at 1.63 in and stops it at 0.9 in, a small band. Short cycles are normal on this design. Frequent runs with little inflow usually mean water is draining back through a dirty check valve.

Does it work on 230 V?

No 230 V figure appears for this model. Its title, brand chart and description all say 115 V, unlike Aquastrong's CDS320 tank pump, whose title also names 230 V as an option.