Quick verdict
Pick the VCMA-15ULS when an air handler, dehumidifier or condensing furnace needs its water raised a few feet to a laundry sink or floor drain. It draws only 1 A and shares the high-water switch of the bigger VCMA-20. Above a 10 ft climb its flow drops to 25 GPH, so a taller run calls for the larger motor.
Who it fits, and who should skip it
A good fit if
- The drain is only a few feet above the equipment, where the curve still shows 50 GPH at 5 ft.
- You want the cooling or heating unit to stop if the tank fills.
- A basement dehumidifier and a furnace share one collection point.
Look elsewhere if
- Your tubing climbs past about 10 ft to an attic or upper floor.
- You run on 230 V; this model is listed for 115 V only.
Specifications
Motor
| Horsepower | 1/50 HP |
|---|---|
| Voltage | 115 V, 60 Hz |
| Amps and watts | 1 A, 60 W |
| Motor type | Thermally protected, fan-cooled, stainless steel shaft |
Figures: Little Giant VCMA-15 Series spec sheet 995124.
Performance
| Max flow | 65 GPH at 1 ft (through the check valve) |
|---|---|
| Max head | 15 ft (4.6 m) shut-off |
| Flow at 5 ft | 50 GPH |
| Flow at 10 ft | 25 GPH |
| Shut-off pressure | 6.5 PSI |
Figures: Little Giant VCMA-15 Series spec sheet 995124; Little Giant VCMA-15 Series product page.
Switch
| Switch type | Float-operated pump switch with a second high-water (overflow) switch |
|---|---|
| Overflow switch contacts | Wired NO from the factory for equipment shut-down; NC available for an alarm |
Figures: Little Giant VCMA-15 Series spec sheet 995124; Little Giant VCMA Series owner's manual, Form 998086.
Build
| Discharge | 3/8 in OD barbed, built-in check valve |
|---|---|
| Tank | 1/2 gallon ABS, wall-mount tabs |
| Inlets | Three 1-1/8 in diameter (two with cap plugs) |
| Materials | ABS tank, motor cover and volute; glass-filled polypropylene impeller; acetal check valve |
| Max water temperature | 140 °F (60 °C) |
| Power cord | 6 ft with grounded 3-prong plug |
| Weight | 4.4 lb (2 kg) |
| Replacement check valve | Part 154715 |
| Warranty | 12-month limited |
Figures: Little Giant VCMA-15 Series spec sheet 995124; Little Giant VCMA-15 Series product page; Little Giant VCMA Series owner's manual, Form 998086.
Versions
Little Giant sells four VCMA-15 versions on one motor and tank. They differ only in the overflow switch and in whether tubing comes in the box.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| VCMA-15ULS, overflow switch | 554405 | The model on this page; no tubing | View on Amazon |
| VCMA-15ULST, switch and tubing | 554415 | Adds 20 ft of 3/8 in ID vinyl tubing; 5.8 lb | View on Amazon |
| VCMA-15UL, base model | 554401 | No overflow switch, no tubing | View on Amazon |
| VCMA-15ULT, tubing only | 554411 | Tubing included but no overflow switch | View on Amazon |
Figures: Little Giant VCMA-15 Series spec sheet 995124; Little Giant VCMA-15 Series product page.
Installation and setup
Choose a level shelf or floor spot lower than the coil drain, leaving the vents around the motor housing open. Remember that the mounting surface carries the pump plus a full tank of water; the slots at each end of the tank allow wall mounting instead. A cardboard piece locks the float for shipping and must come out, or the pump will never start and the tank will spill.
Bring each drain line into an inlet with an angled cut so the end cannot seal on the tank floor, and cap any opening you leave unused. Fit tubing of 3/8 in ID or smaller to the barbed outlet with a hose clamp (not supplied). Lift it vertically first, then let it fall gently toward a drain at or below the pump base where you can, which sets up a siphon and helps the motor. A wire run to a dedicated outlet with steady power completes the job; a GFCI circuit is needed where code calls for one.
Switch and sizing notes
The main float cycles the motor on its own. The overflow float works a separate low-voltage switch with two black leads. Wired as delivered, it breaks the thermostat circuit when the water climbs too high, which stops the air conditioner or furnace from producing more. Under the motor cover, the lead can be moved to the NC terminal so a high level closes a circuit for a buzzer or relay you supply.
The maker's figures, measured through the check valve, are 65 GPH at 1 ft, 50 GPH at 5 ft and 25 GPH at 10 ft. Little Giant also says total inflow must stay below the pump's output, and that the tubing should not rise more than 75% of the total head. For a run that heads toward the ceiling, the VCMA-20ULS keeps the same footprint with a stronger motor. The furnace and AC condensate pump list lines up other choices.
Ownership and maintenance
Plan a check twice a year, and more often when the pump serves a busy system. With the power off, lift the cover by its slot, clear any sludge so the floats swing freely, and clean the tank with mild soap and warm water. Backwash the check valve over a sink; a clogged valve is a frequent cause of a pump that hums while the water stays put.
Furnace condensate can be acidic enough to pit metal parts, so rinse the tank with fresh water at each visit. To confirm the switch works, raise the overflow float by hand with the cover off and watch the equipment stop. Little Giant backs the pump for 12 months from purchase.
Pros and cons
Pros
- Draws 1 A, the lightest motor in the VCMA range.
- Overflow switch included on this version.
- Four item numbers cover with or without switch and tubing.
- Replacement check valve has its own part number.
Cons
- Only 25 GPH remains at a 10 ft lift.
- No 230 V version in this series.
- Small tank for large-capacity coils.
Alternatives worth comparing



Compared with and featured in
Final verdict
The VCMA-15ULS is the sensible choice for a short, upward run from a furnace, coil or dehumidifier, with a switch that stops the equipment before water spills. Once the climb nears 10 ft, step up to the VCMA-20ULS.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
What does the S in VCMA-15ULS stand for?
It marks the safety switch. The VCMA-15ULS, item 554405, has the high-water overflow switch; the VCMA-15UL lacks it. A T adds tubing, so the VCMA-15ULST has both the switch and 20 ft of vinyl tubing.
Is the VCMA-15ULS strong enough for an attic air handler?
Only when the drain sits a short way above or below it. Flow falls to 25 GPH at 10 ft and stops at 15 ft. Attic units that must push water down are easy; upward climbs of more than a few feet suit the VCMA-20.
Why does my VCMA-15ULS run but not empty the tank?
Common causes are slime in the check valve, a kinked tube or a line rising beyond what the pump can lift. Unplug it, remove and backwash the valve, then look over the tubing for kinks before replacing anything.
Can the VCMA-15ULS take water from a condensing furnace?
Yes. Little Giant lists condensing furnaces and boilers, and the tank handles water up to 140 °F. Rinse it with fresh water during upkeep, since acidic condensate left standing can pit parts.