Quick verdict
The FUJ-40L is the larger-flow box in Fujiwara's mini range, meant to hang on the wall below a ductless head, a dehumidifier or an ice maker. Probe sensing removes the float that sticks in other small pumps. Against that, the listing contradicts itself on head, flow and voltage, says nothing about an overflow contact, and gives no warranty term.
Who it fits, and who should skip it
A good fit if
- A ductless head or dehumidifier where a small box can hang on the wall below the drain.
- You have had float pumps stick and want probe sensing instead.
- Quiet running matters in a bedroom or office.
Look elsewhere if
- You need a safety contact to shut the equipment off; none is described for this model.
- A furnace or several appliances must drain into one pump.
Specifications
Performance
| Max flow | 40 L/h per bullet; brand charts say 10.5 GPH and 12.6 GPH |
|---|---|
| Max head | 33 ft per bullet; 32 ft per spec row and chart |
| Equipment size | Air conditioners of 1 to 5 HP (3700W) |
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L); Amazon listing B07XBWNVX8, Fujiwara FUJ-24S, brand comparison chart.
Motor
| Voltage | 100-220V per bullet; chart says 110-220V, 50-60Hz; spec row 110 V |
|---|---|
| Power draw | 3 W; no draw on standby |
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L).
Switch
| Switch type | Probe water sensing, automatic start and stop (no float) |
|---|---|
| Overflow contact | Not stated in the listing |
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L).
Build
| Tank capacity | 150 ml (brand chart) |
|---|---|
| Noise | Below 18 dB per bullet; 18-21 dB per chart |
| Dimensions | 6.7 in x 6.7 in x 4.2 in |
| Weight | 1.8 lb (FUJ-24S listing chart) |
| Construction | ABS plastic, white, wall-mounted, indoor use only |
| In the box | Pump body, power line, outlet tube |
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L); Amazon listing B07XBWNVX8, Fujiwara FUJ-24S, brand comparison chart.
Ownership
| Warranty | Not stated in the listing |
|---|
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L).
Versions
Fujiwara sells the same family in L, S and B bodies at two flow sizes. Only this listing has a saved product page here.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| FUJ-40L, wall-mounted, white | FUJ-L | 40 L/h, 150 ml tank, for A/C up to 5 HP | View on Amazon |
| FUJ-24L | Not stated in the listing | Same body, smaller flow (6.3 GPH in the brand chart) | Not linked |
| FUJ-40S and FUJ-40B | Not stated in the listing | Other bodies at the larger flow size, 200 ml tank in the brand chart | Not linked |
Figures: Amazon listing B07PR365TV, Fujiwara FUJ-40L (model row FUJ-L).
Installation and setup
Hang the box on the wall below the drain outlet of the indoor unit, dehumidifier or ice maker, so condensate can fall into it. The listing marks it for indoor use only, so keep it out of an attic exposed to frost or a damp crawl space.
Connect the drain to the inlet with a short, falling hose; any rise before the pump traps water in the line. Then run the supplied outlet tube up to its highest point and let it slope down to a drain or outside. A long climb wastes much of a pump this small, so keep the vertical part as short as the job allows.
The listing does not describe the wiring for this body beyond the power line, and it names no overflow contact. Use a plug-in supply where you can, and if the head has a condensate safety input, fit a separate float switch or alarm rather than assuming the pump provides one. An electrician should handle any hard-wired connection.
Switch and sizing notes
Instead of a float, the FUJ-40L uses probes that detect water in the 150 ml tank and start the motor, then stop it when the level drops. Fujiwara's point is that probes cannot hang up or lose magnetism the way a float can. Probes still foul with slime, so they need the same cleaning a float does.
Fujiwara matches this body to air conditioners of 1 to 5 HP and quotes 40 L/h, which its charts show as 10.5 GPH and, on a second listing, 12.6 GPH. Head is printed as 33 ft in the bullets and 32 ft in the spec row. Plan on the lower figures, and keep the climb well under them, because no curve shows flow at real heights. For a smaller head, the lower-flow FUJ-24 sizes are quieter.
Ownership and maintenance
Check the inside of the tank and the probes every few months during cooling season. A film of algae or dust can bridge the probes and keep the pump running, or coat them so the pump never starts. Disconnect power, rinse the tank and wipe the probes clean.
Look at the outlet tube for kinks where it bends at the wall. Because no warranty term appears on the listing and Fujiwara publishes no maker manual, keep the order details and the paper instructions from the box, which are the only setup notes you will have.
Pros and cons
Pros
- Probe sensing, so no float to stick.
- Listed at 3 W with no standby draw.
- Larger flow size of Fujiwara's mini range.
Cons
- Head, flow and voltage figures conflict across the listing.
- No overflow or alarm contact described.
- No warranty term or maker document.
Alternatives worth comparing



Final verdict
The FUJ-40L is a reasonable float-free mini pump for a single indoor unit or dehumidifier with a short climb. Its listing leaves real gaps, chiefly the missing overflow contact, so pair it with a separate safety switch where the equipment allows.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is the Fujiwara FUJ-L the same as the FUJ-40L?
Yes, on this listing. Amazon's model and part number rows say FUJ-L, while the selected variation and the title name the FUJ-40L. The 40 refers to its 40 L/h flow size, against the 24 L/h of the FUJ-24 models.
Why does the listing say 5 HP?
That figure is the size of air conditioner the pump suits, 1 to 5 HP or about 3700W of cooling, not the pump motor. The pump itself is listed at 3 W. A spec row that reads 5 hp is a data error.
Does the FUJ-40L work on a higher-voltage supply?
The bullets describe a wide 100-220V input and the brand chart says 110-220V at 50-60Hz, so it is meant for both. The spec row lists 110 volts only. Check the label on the unit before wiring it to a higher supply.
Can it stop the air conditioner if it fails?
This listing does not describe a safety or alarm contact for the L body. If your unit has a condensate safety input, add a separate float switch or alarm, because the pump alone may not protect against overflow.