Quick verdict
Choose the P382LE51 for a new basement bathroom where the slab can only be dug about two feet deep, or where you want the basin, cover, pump and float rod chosen to match. Its floats sit on a removable QuickTree rod, so they can be serviced without lifting the pump. Buyers replacing only a worn pump in a sound basin should look at the LE51A alone.
Who it fits, and who should skip it
A good fit if
- You are roughing in a basement bathroom and need a complete, sealed ejector system.
- Digging is limited; the Pro380 basin is 24 in tall rather than 30 in.
- You want float service without disconnecting plumbing or pulling the pump.
Look elsewhere if
- Your existing basin is sound and only the pump has failed.
- The system goes outdoors without the optional ARC18 access riser.
Specifications
Pump
| Horsepower | 1/2 hp |
|---|---|
| Voltage | 115 V, single phase |
| Full-load amps | 12 A (22.5 A locked rotor) |
| Max flow | 141 GPM at 5 ft (LE50-Series pump) |
| Flow at 10 ft | 118 GPM (LE50-Series pump) |
| Max head | 24 ft shut-off (LE50-Series pump) |
| Solids handling | 2 in |
| Power cord | 10 ft (25 ft on P382LE51-2) |
Figures: Liberty Pumps Pro380-Series system specification R05/2026; Liberty Pumps LE50-Series pump specification; Liberty Pumps LE50-Series sales literature LLIT001500.
Basin
| Basin | Rotationally molded polyethylene, 24.38 in diameter, 24 in tall |
|---|---|
| Capacity | 41 gallon system |
| Cover | Injection molded polypropylene with separate access cover |
| Discharge | 2 in NPT through the cover, schedule 80 PVC pipe |
| Vent | 2 in or 3 in NPT on the cover |
| Inlet | 4 in hub molded into the tank, for a no-hub coupling |
Figures: Liberty Pumps Pro380-Series system specification R05/2026; Liberty Pumps installation manual 7225000L, Pro370, Pro380 and 700-Series systems.
Controls
| Switch type | Factory-set floats on a removable QuickTree rod |
|---|---|
| Alarm | Optional alarm float on the QuickTree |
Figures: Liberty Pumps Pro380-Series system specification R05/2026; Liberty Pumps installation manual 7225000L, Pro370, Pro380 and 700-Series systems.
Build
| Extension | Optional 8 in basin extension |
|---|---|
| Warranty | 3-year limited |
Figures: Liberty Pumps Pro380-Series system specification R05/2026; Liberty Pumps installation manual 7225000L, Pro370, Pro380 and 700-Series systems.
Versions
Pro380 model numbers combine the basin and discharge size (P382 is 2 in, P383 is 3 in) with the pump inside.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| P382LE51, 1/2 hp, 115 V | P382LE51 | 2 in discharge, 10 ft cord | View on Amazon |
| P382LE41, 4/10 hp, 115 V | P382LE41 | Same basin with the smaller LE40-Series pump, 12 A | View on Amazon |
| P382LE51SD-2, side discharge | P382LE51SD-2 | 2 in side discharge, 25 ft cord, float on the pump | Not linked |
| P383LE51, 3 in discharge | P383LE51 | 1/2 hp pump, 3 in discharge connection | Not linked |
| P382LE52, 208–230 V | P382LE52 | 1/2 hp, 6.8 A at 208–230 V | Not linked |
Figures: Liberty Pumps Pro380-Series system specification R05/2026; Amazon listing B002YR9Y9U; Amazon listing B002YRDRP2.
Installation and setup
Dig a hole only as large as needed, leaving about 8 in of clearance around the basin, and bed it on compacted pea gravel or washed crushed stone rather than sand or native soil. Liberty recommends setting the top lip level with the finished floor. Connect the fixture drain to the 4 in inlet hub with a no-hub coupling.
On top, thread the discharge into the cover, add a union just above it, then a check valve and a gate or ball valve. Liberty says a non-grinder Pro system must keep at least a 2 in discharge. The vent must be no smaller than the discharge and should tie into the building vent or rise through the roof on its own pipe.
Indoor installs need nothing more, but outdoor or buried installs need the ARC18 access riser. The cover is not traffic rated, so keep heavy equipment off the backfill while the slab is poured.
Switch and sizing notes
On vertical discharge Pro380 systems the pump itself has no switch. Its cord plugs into the back of a piggyback float cord, and the float hangs from a stainless QuickTree rod under the separate access cover. Liberty presets the floats at the factory and says they should not be moved, since field changes can upset the pump and alarm points.
The pump inside belongs to the LE50-Series, rated for 141 GPM at 5 ft and 118 GPM at 10 ft, with no flow at 24 ft. Add your vertical lift to pipe friction and check the result against those figures. The shallow 41 gallon basin stores less between starts than a 30 in deep tank, so keep heavy drain loads in mind for larger households.
Ownership and maintenance
To inspect the floats, unbolt the access cover and lift the QuickTree out; the plumbing stays connected. When it goes back, seat each cord in its rubber channel and plug any unused channel, then torque the bolts to the value Liberty prints so sewer gas stays inside.
Liberty backs the system with a 3-year limited warranty from the date of purchase, proven by a dated receipt showing the model and serial number. Keep flushable wipes and grease out of the drains, since this is a non-grinder pump.
Pros and cons
Pros
- Complete system: basin, cover, pump, piping and float rod.
- Shallow 24 in basin suits limited digging.
- Floats lift out without touching the pump.
- Cast iron LE-Series pump with 2 in solids handling.
Cons
- Outdoor or buried use needs an extra riser.
- Shallower basin holds less between cycles.
- Factory float settings are not meant to be changed.
Alternatives worth comparing



Compared with and featured in
Final verdict
The P382LE51 takes the guesswork out of a basement bathroom rough-in by matching basin, cover, pump and floats. Pick it when digging depth is limited or float access matters; if the basin is already in the floor, buy the pump alone.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How big is the Liberty P382LE51 basin?
The Pro380 basin is about 24.38 in across and 24 in tall, and Liberty calls it a 41 gallon system. An optional 8 in extension adds depth where the drain line enters lower. Its shallow shape is the main reason to pick it over the taller Pro370 basin.
Where is the float switch on the P382LE51?
On vertical discharge Pro380 systems the float hangs from a stainless QuickTree rod under a separate access cover, not on the pump. You unbolt that cover and lift the rod out to check or replace a float. Side discharge versions put the float back on the pump.
Does the P382LE51 include an alarm?
An alarm float is optional. Liberty ships it on top of the system when ordered and mounts it on the QuickTree. The Uniform Plumbing Code calls for an audible and visual alarm on sewage systems, so add one if your order did not include it.
Can I use 1-1/2 in pipe for the discharge?
Not with this non-grinder system. Liberty's manual says its non-grinder Pro-Series systems must keep a discharge of at least 2 in. Only ProVore grinder systems may be reduced to 1-1/4 in pipe.