Cast iron sewage ejector · Zoeller

Zoeller M267 Waste-Mate Sewage Pump

The Zoeller M267 is a 1/2 HP cast iron sewage ejector that passes 2 in spherical solids, rated on the current data sheet for 115 GPM at 5 ft of head and 20.5 ft at shut-off.

Model M267 · part number 267-0001 · Updated November 2026

Horsepower
1/2 HP
Voltage
115 V, single phase, 60 Hz (M267)
Max flow
115 GPM at 5 ft
Max head
20.5 ft (6.2 m) shut-off head
Discharge
2 in NPT

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

The M267 is a sensible choice for a basement bathroom or laundry basin that has to lift waste one storey to the building sewer. Its cap, motor housing, pump housing and base are all cast iron, and the float works inside a guard. The limit is lift: flow falls to 45 GPM by 15 ft, so tall or long discharge runs call for a larger pump or a grinder.

Who it fits, and who should skip it

A good fit if

  • Your basement toilet, shower and sink drain to an 18 in by 30 in or larger sealed basin.
  • The vertical lift to the sewer line is about 10 ft or less, where the table still shows 85 GPM.
  • You prefer a cast iron base over the plastic base used on the smaller Model 264.

Look elsewhere if

  • Total head nears the 20.5 ft point where the curve runs out.
  • Waste must travel a long way through small pipe, which is grinder pump work.

Specifications

Motor

Horsepower1/2 HP
Voltage115 V, single phase, 60 Hz (M267)
Full-load amps9.4 A at 115 V
Motor typePermanent split capacitor, oil-filled, 1725 RPM
Motor protectionAutomatic-reset thermal overload (single phase)

Figures: Zoeller technical data sheet FM2789, Model 267.

Performance

Max flow115 GPM at 5 ft
Flow at 10 ft85 GPM
Flow at 15 ft45 GPM
Max head20.5 ft (6.2 m) shut-off head

Figures: Zoeller technical data sheet FM2789, Model 267.

Switch

Switch typeIntegral float-operated mechanical switch in a guard
On / off levelsOn at 12 in, off at 4 in

Figures: Zoeller technical data sheet FM2789, Model 267; Zoeller Model 267 product page.

Build

Discharge2 in NPT
Solids handling2 in spherical solids, vortex impeller
ConstructionCast iron cap, motor housing, pump housing and base; thermoplastic impeller
Power cord10 ft automatic, 15 ft nonautomatic
Max liquid temperature130 °F
Weight47.5 lb (22 kg)
Minimum basinSimplex 18 x 30 in; duplex 30 x 36 in
Listings“Tested to Standard UL778 and Certified to CSA Standard C22.2 No. 108”
Warranty3-year limited

Figures: Zoeller technical data sheet FM2789, Model 267; Zoeller Model 267 product page; Zoeller installation instructions FM2676.

Versions

The 267 body is sold in many switch, voltage and phase versions; the M prefix marks the 115 V automatic pump with the built-in float.

VersionPart numberWhat differsListing
M267, automatic, 115 V267-0001Integral float switch, 9.4 A, 10 ft cordView on Amazon
M267, automatic, 115 V, longer cordNot stated on the listingListing gives a 15 ft cord; Zoeller offers longer cords as optionsView on Amazon
N267, nonautomatic, 115 VNot on the data sheetNo switch; needs a piggyback float or control panel, 15 ft cordNot linked
BN267, piggyback float, 115 VNot on the data sheetVariable-level piggyback switch for a wider pumping rangeNot linked
D267, automatic, 230 VNot on the data sheetIntegral float switch, 4.7 A at 230 VNot linked

Figures: Zoeller technical data sheet FM2789, Model 267; Zoeller Model 267 product page; Amazon listing B003Y5F7J2; Amazon listing B00C6XTRYE.

Installation and setup

The M267 belongs in a sealed sewage basin. Zoeller's minimum for a single pump is 18 in across and 30 in deep, and the lid needs gas-tight seals with a vent pipe carrying odors outdoors. Clean the basin floor so the cast iron base sits flat and level, and keep the float guard clear of the basin wall.

Run 2 in pipe from the discharge and fit a Zoeller unicheck or another union and check valve just above the basin, so the pump can be lifted out later. When a check valve is used, drill a vent hole of about 3/16 in in the discharge pipe, level with the top of the pump and below the cover; a small stream from it while the pump runs is normal.

Use a dedicated, grounded circuit and plug in directly. Zoeller warns against extension cords and against flushing anything but toilet paper into a non-grinder system: wipes, towels and hygiene products are its main enemies.

Switch and sizing notes

The automatic switch is a snap-action unit with a polypropylene float inside a stainless guard. It starts the pump at about 12 in of liquid and stops it at about 4 in. In an 18 in basin, Zoeller's related Waste-Mate sheet estimates about eight gallons moved per cycle with this style of switch, which gives short, frequent runs after a flush.

For sizing, add the vertical lift from the basin to the high point of the line and a friction allowance for the pipe length. The current FM2789 table reads 115 GPM at 5 ft, 85 GPM at 10 ft and 45 GPM at 15 ft. Older sales literature quoted 128 GPM and 21.5 ft; use the newer data sheet.

Ownership and maintenance

The motor is oil-filled with carbon and ceramic seals and needs no lubrication. Inspect and run the system at least every three months, clear the vent hole, and watch for a float that sticks on grease. A high-water alarm on a separate circuit is cheap insurance in a finished basement.

Zoeller covers the 267 with a 3-year limited warranty when bought from an authorized seller, and service must go through its authorized centers. Allow the pump to sit unplugged for a couple of hours before opening anything, because the oil inside stays hot and pressurized.

Pros and cons

Pros

  • All cast iron housings and base, epoxy powder coat.
  • Passes 2 in spherical solids through a vortex impeller.
  • Guarded float keeps debris away from the switch arm.
  • Many switch, voltage and three-phase versions on one body.

Cons

  • Flow drops steeply above about 10 ft of head.
  • Fixed on and off points on the automatic M267.
  • Plastic impeller on standard single-phase units.

Alternatives worth comparing

Final verdict

Pick the M267 for an ordinary basement bathroom basin where the lift to the sewer is moderate and you value cast iron throughout. Read flow at your own total head from the data sheet, and look at a grinder when the line is long or nears the shut-off head.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

How much head can the Zoeller M267 handle?

The current data sheet gives a shut-off head of 20.5 ft, where flow stops entirely. Useful sewage flow lives lower down: 85 GPM at 10 ft and 45 GPM at 15 ft. Plan the installation so the total head, including pipe friction, stays well below the shut-off figure.

Can the M267 pump septic effluent?

Zoeller lists residential and light commercial sewage plus dewatering as its applications. Its installation sheet adds that sewage pumps may serve effluent duty where code permits, but recommends nonautomatic pumps with external level controls for septic tank effluent, so the N267 or BN267 is the better fit there.

What is the difference between the M267 and the M264?

Both pass 2 in solids through a 2 in discharge. The M264 is a 4/10 HP pump with an engineered plastic base, rated for 90 GPM and 18 ft of head. The M267 steps up to 1/2 HP with a cast iron base and 20.5 ft of shut-off head.

Why does water spray from a small hole in the discharge pipe?

That is the vent hole Zoeller asks for whenever a check valve is installed. It lets trapped air escape so the pump does not air lock. A thin stream while the pump runs is expected; if it stops, clear the hole, because a blocked vent can leave the pump spinning without moving waste.