Cast iron sewage ejector · Superior Pump

Superior Pump 93501 Cast Iron Sewage Pump

The Superior Pump 93501 is a 1/2 HP cast iron sewage pump with a piggyback tethered float, rated by the maker for 4,800 GPH with no lift and a maximum lift of 25 ft.

Model 93501 · part number 93501 · Updated November 2026

Horsepower
1/2 HP
Voltage
120 V, single phase, 60 Hz
Max flow
4,800 GPH (80 GPM) at 0 ft
Max head
25 ft maximum lift
Switch type
PiggyBack tethered float
Discharge
2 in NPT, side outlet

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

The 93501 is a plain, serviceable ejector for a basement bathroom or laundry that drains into a sealed sewage basin. It passes 2 in solids and moves 3,600 GPH at a 10 ft lift. The limits are the short warranty and a tether float that needs a wide basin to swing freely.

Who it fits, and who should skip it

A good fit if

  • You are replacing a worn 1/2 HP ejector in a sealed basin with a 2 in discharge line.
  • Your vertical lift from the basin to the gravity sewer is around 10 ft, where the maker still lists 60 GPM.
  • You want a float you can plug and unplug yourself, so the pump can be run by hand for a check.

Look elsewhere if

  • Your basin is narrow and a tethered float would brush the wall or the pipe.
  • The sewage must climb close to 20 ft or more, where the chart drops to 25 GPM and lower.
  • You want a long warranty; the maker covers this pump for one year.

Specifications

Motor

Horsepower1/2 HP
Voltage120 V, single phase, 60 Hz
Current7.6 A
Motor typePSC motor, copper windings, dual o-ring seals
Motor protectionBuilt-in thermal overload, resets after cooling

Figures: Superior Pump 93501 product page; Superior Pump sewage pump owner's manual, models 93501, 93507, 93511 (revised 10-08).

Performance

Max flow4,800 GPH (80 GPM) at 0 ft
Max head25 ft maximum lift
Flow at 5 ft4,080 GPH (68 GPM)
Flow at 10 ft3,600 GPH (60 GPM)
Flow at 15 ft2,640 GPH (44 GPM)
Flow at 20 ft1,500 GPH (25 GPM)
Flow at 25 ft300 GPH (2 GPM)

Figures: Superior Pump 93501 product page; Superior Pump sewage pump owner's manual, models 93501, 93507, 93511 (revised 10-08).

Switch

Switch typePiggyBack tethered float
On / off levelsOn at 16 in, off at 8 in (maker product page)

Figures: Superior Pump 93501 product page.

Build

Discharge2 in NPT, side outlet
Solids handling2 in solids, thermoplastic vortex impeller, bottom suction
ConstructionCast iron motor casing, pump body and base; stainless steel shaft
Shaft sealCarbon / ceramic / stainless steel
Power cord10 ft
Liquid temperature35 °F to 120 °F, intermittent use
Circuit15 A circuit
Warranty1-year limited

Figures: Superior Pump 93501 product page; Superior Pump sewage pump owner's manual, models 93501, 93507, 93511 (revised 10-08).

Versions

The 93501 is the tethered-float member of a three-model sewage line in the owner's manual; the others use different switch parts.

VersionPart numberWhat differsListing
93501, tethered float, 120 V93501PiggyBack tether float, 10 ft cord, 2 in NPT dischargeView on Amazon

Figures: Superior Pump 93501 product page; Superior Pump sewage pump owner's manual, models 93501, 93507, 93511 (revised 10-08); Amazon listing B000IJSVXQ.

Installation and setup

Superior's manual starts with the old pump: cut the power, lift it out and, where you can, replace the old piping rather than reuse it. Set the 93501 on a solid footing at one side of the basin, leaving at least 1 in of clearance so the float can travel from bottom to top without touching the wall.

Fit a full-flow swing check valve, the same 2 in size as the discharge, as close to the pump as practical, and run the line in Schedule 40 pipe. The manual treats a fully sealed, approved sewage tank and a vent pipe as required for sewage, because the gases are both foul and dangerous.

The maker wants a grounded outlet within 6 ft of the pit, ideally GFCI protected, wired by a qualified electrician. Plug the float's piggyback plug into the outlet and the pump plug into the back of it. Fill the basin with a hose and watch one full cycle before closing the lid.

Switch and sizing notes

The tethered float hangs from the pump and swings up as the basin fills. Superior's current product page gives the pump starting at 16 in and stopping at 8 in. The older owner's manual prints a factory setting of 14 in on and 6 in off and says the tether can be adjusted, so expect some spread between units and set it to suit your basin depth.

For sizing, add the vertical lift from the basin floor to the highest point of the line and an allowance for horizontal pipe and fittings. Then read the chart: 4,080 GPH at 5 ft, 3,600 GPH at 10 ft and 2,640 GPH at 15 ft. Past 20 ft the pump barely moves water. The sizing calculator helps estimate total head, and the ejector, grinder and sump pump guide covers when a solids-handling pump is the right type.

Ownership and maintenance

The motor is oil-filled with a carbon and ceramic seal, so routine care means keeping the float free and the line clear. If the pump runs but moves little water, the manual's list is short: a blocked or frozen pipe, a check valve stuck or fitted backwards, low voltage, or an air lock. Clear the small airlock hole with a paper clip.

Do not run it dry, since the water cools the motor; the thermal overload is a backstop and wears with repeated trips. Coverage is one year. Keep the receipt, because the manual allows an exchange while an insurance claim keeps the failed pump.

Pros and cons

Pros

  • Cast iron body, motor casing and base.
  • Passes 2 in solids through a vortex impeller.
  • Full performance chart printed to 25 ft.
  • Piggyback float allows a manual run for checks.

Cons

  • One-year warranty is short for a sewage pump.
  • Tether float needs a wide basin.
  • Switch levels differ between the manual and the product page.

Alternatives worth comparing

Final verdict

Pick the 93501 for a straightforward sewage basin with a lift near 10 ft and room for a tethered float. If the basin is tight or you want longer coverage, look at an ejector with a built-in switch or a longer warranty from the same hub.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

How high can the Superior 93501 pump sewage?

Superior rates it for a maximum lift of 25 ft, but at that height its chart shows only 300 GPH. A realistic working range is up to about 15 ft, where the pump still moves 2,640 GPH, or 44 GPM, through a 2 in line.

Can the 93501 be used as a sump pump?

It will move clear water, and the product page mentions groundwater, but it is built around a 2 in solids passage, a vortex impeller and sealed-basin installation. For a plain basement sump, a dedicated sump pump with a guarded switch is usually simpler to fit.

Why does the listing show a different horsepower?

One Amazon data row lists the horsepower as 2, which conflicts with the listing's own title and with Superior's product page and manual. Both maker documents give the motor as 1/2 HP, drawing 7.6 A at 120 V.

Does the 93501 need a vent?

The pump itself does not vent, but the sewage basin does. Superior's manual calls for a sealed, approved tank and shows a vent pipe in its typical installation drawing, along with Schedule 40 pipe for the discharge.