Electronic pump switch ยท HydroCheck

HydroCheck HC6000 Electronic Float Switch

The HydroCheck HC6000 is an electronic pump switch with no moving float: two sensors read the water, and a built-in 85 dB alarm sounds on high water or a pump that draws no current.

Model HC6000 · part number HC6000v2 · Updated November 2026

Switch type
Electronic hi-lo dual sensor, no moving float
Voltage
120 VAC
Cable length
12 ft
Alarm
Built-in, 85 dB

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

Worth a look when mechanical floats keep sticking with grit or iron bacteria, and when you want an alarm without a second box. It runs on 120 VAC and needs a sound ground for its sensors. Information comes from the seller's listing only; there is no maker manual to read before buying.

Who it fits, and who should skip it

A good fit if

  • Floats in your pit keep jamming on debris.
  • You want a switch and a high-water alarm in one unit.
  • You can bond the sensor ground as the listing describes.

Look elsewhere if

  • You want switch levels documented in a maker manual first.
  • The pump runs on anything other than 120 VAC.

Specifications

Electrical

Switch typeElectronic hi-lo dual sensor, no moving float
Voltage120 VAC
Cable length12 ft

Figures: Amazon listing B006AU4L4U (HC6000v2).

Alarm

AlarmBuilt-in, 85 dB
High-water alarmThree beeps if water stays above the hi-sensor 25 seconds after two anti-airlock cycles
Pump fault alarmTwo beeps if no motor current was sensed in the last cycle
SilenceSmart Button press silences an alarm for 24 hours

Figures: Amazon listing B006AU4L4U (HC6000v2).

Build

Part numberHC6000v2
Maker named on the listingSTAK Enterprises, Inc.
OriginMade in USA (per the listing)
Unit size2.75 x 3.75 x 2.5 in

Figures: Amazon listing B006AU4L4U (HC6000v2).

Installation and setup

The HC6000 hangs on the discharge pipe with its sensors in the pit, and the pump plugs into it in place of a mechanical float. If the pump has its own float switch, that switch has to be disabled, held in the on position, or the controller will report a missing pump current. The listing also warns that a weak or missing ground reference triggers a flashing light and steady alarm, so follow the ground-wire step in the instructions.

After plugging in, the light shows red with the pump off and green while it runs. Fill the pit with a hose and watch at least two full cycles before closing the lid.

Compatibility

Sold for sump and utility pumps on 120 VAC. The listing does not print a current limit for the switched outlet, so check with the seller before using it on a large pump. Because it detects the pump through current draw, it also flags a pump that is unplugged or seized. For how it compares with tethered and vertical floats, see the switch types guide.

Ownership and maintenance

With no float to stick, upkeep is mostly cleaning scale off the sensors and checking the alarm. Holding the Smart Button while the light is red runs the pump by hand, which makes a quick monthly check easy. Holding it while plugging in resets every setting to the factory defaults, so use that only when troubleshooting. Test the alarm itself now and then as well, because it is the part you rely on when you are away.

Pros and cons

Pros

  • No mechanical float to jam.
  • Alarm built into the switch body.
  • Flags a pump that draws no current.

Cons

  • No maker manual or current rating to review before purchase.
  • Needs a good ground reference to work properly.

Alternatives worth comparing

Final verdict

Choose the HC6000 for a pit where floats keep jamming and you want an alarm built in. Accept that its details come from the seller's listing, and plan for a good ground connection.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

What do the HC6000 beeps mean?

Per the listing, two beeps mean no motor current was sensed in the previous cycle, so the pump may be unplugged or failed. Three beeps are the high-water alarm: water stayed above the upper sensor after two anti-airlock attempts.

Do I have to remove my pump's float?

The mechanical switch must not be left active. Disable it or hold it on, otherwise the HC6000 cannot control the pump and will raise the missing-current alarm on the next cycle.

Can I quiet the alarm without unplugging it?

Yes. A short press of the Smart Button silences an active alarm for a day, and a long press disables it until the switch is reset. Find the cause before you silence it.

Does the HC6000 need a ground wire?

The sensors work against a ground reference. The listing says a weak or missing ground produces a flashing light and a steady alarm, and points to the instructions on adding a ground wire.