Quick verdict
A tidy upgrade for a narrow pit, where a tethered float would rub the wall. The float slides on a rod between adjustable stops, so you can lower the shut-off point and pump the pit down further each cycle. The current rating suits typical household sump pumps rather than large ones.
Who it fits, and who should skip it
A good fit if
- Your pit is narrow and a tether float keeps catching.
- You want to set the start and stop points yourself.
- The pump draws no more than 10 A.
Look elsewhere if
- The pump is on a higher voltage or needs a heavier switch.
- You need a wire-lead float for a control panel.
Specifications
Electrical
| Switch type | Vertical float on a rod, piggyback plug, normally open |
|---|---|
| Rating | 10 A at 120 VAC |
| Contacts | Gold-plated |
| Power cord | 10 ft with piggyback plug |
Figures: Amazon listing B0939NZ79M (PumpSpy VS-100).
Use
| Rated use | Sump, sewage and effluent |
|---|---|
| Cycle rating | Up to one million cycles (seller claim) |
Figures: Amazon listing B0939NZ79M (PumpSpy VS-100).
Build
| In the box | Assembled switch, mounting bracket, stainless hose clamp |
|---|---|
| Weight | 1.2 lb |
Figures: Amazon listing B0939NZ79M (PumpSpy VS-100).
Installation and setup
The VS-100 arrives assembled. Strap its bracket to the discharge pipe with the stainless hose clamp so the rod stands upright and the float slides freely, clear of the pump and the pit wall. Set the lower stop high enough that the pump always shuts off before the water uncovers its intake, and the upper stop below the drain tile inlet.
Plug the switch into a grounded 120 V outlet and the pump into its piggyback socket. A pump with a built-in switch must have it held on or set to manual. Fill the pit and check the start and stop points over a few cycles, then tighten everything.
Compatibility
PumpSpy sells the VS-100 as a universal replacement for sump, sewage and effluent pumps on 120 VAC with a running current within 10 A. It is a good swap for a pump whose own vertical switch has worn out, provided the pump can be run in manual mode or its switch held on. It does not connect to PumpSpy's monitoring app on its own. See the switch types guide for how vertical and tethered floats differ.
Ownership and maintenance
Grit and mineral build-up on the rod are what slow a vertical float, and the listing says the materials are chosen to limit sticking. Even so, wipe the rod when you clean the pit and run a bucket test every few months. Narrowing the stops too far makes the pump short-cycle, so use the basin cycle calculator if you are unsure.
Pros and cons
Pros
- Fits pits too narrow for a tether.
- Adjustable start and stop points.
- Gold-plated contacts resist pitting.
Cons
- Current rating limits it to typical household pumps.
- Cycle rating is a seller claim with no maker manual.
Alternatives worth comparing



Compared with and featured in
Final verdict
Pick the VS-100 for a narrow pit or when you want to set your own start and stop points on a household sump pump. Choose a heavier-rated switch for large pumps.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How long does the PumpSpy VS-100 last?
PumpSpy claims a rating of up to one million on-off cycles. Real life depends on how often your pump runs and how much grit is in the pit, so a yearly look at the rod and float is still worth doing.
Can I lower the shut-off level with the VS-100?
Yes. The stops on the rod are adjustable, so you can drop the off point to pump more water each cycle. Keep it above the pump intake so the pump never runs dry.
Is the VS-100 a good swap for a tethered switch?
Often, yes. A vertical float needs far less side room, so it suits pits where a tether keeps catching on the wall or pipes. Check that your pump can run with its own switch held on.
Can the PumpSpy VS-100 control a sewage pump?
The listing names sump, sewage and effluent applications on 120 VAC within 10 A. In a sewage basin, keep the rod clear of the inlet and rinse it at each service.