Quick verdict
The RL-SP33PED keeps its motor up on a column, out of the water, and starts on a float stem you can set yourself. That makes it a fair choice for a narrow, shallow pit that sees light, occasional inflow. Red Lion rates it for household duty of two hours or less of running a day and only 600 GPH at 15 ft, so a wet basement or a tall lift needs a submersible.
Who it fits, and who should skip it
A good fit if
- Your pit is narrow, from 13 in across, and no deeper than 24 in.
- Inflow is occasional and the lift is under about 10 ft.
- You want to raise or lower the start level without buying a new switch.
- You like a motor you can see and reach above the water.
Look elsewhere if
- The pump would run for hours in wet seasons; the manual caps daily run time.
- Your discharge climbs near 15 ft, where flow drops to 600 GPH.
- Your pit is deeper than 24 in or you want a sealed cover with no column showing.
Specifications
Motor
| Horsepower | 1/3 HP |
|---|---|
| Voltage | 115 V, 60 Hz |
| Amps | 4.0 A |
| Motor type | PSC, 1,725 RPM, ball bearings, automatic-reset thermal protector |
| Duty | Domestic household service, two hours or less of run time per day |
Figures: Red Lion RLSP33PED thermoplastic pedestal sump pump owner's manual 998776; Red Lion pedestal pump product page.
Performance
| Max flow | 3,300 GPH at 0 ft |
|---|---|
| Flow at 5 ft | 2,800 GPH |
| Flow at 10 ft | 2,040 GPH |
| Flow at 15 ft | 600 GPH |
| Max head | 16 ft (4.9 m) shut-off |
Figures: Red Lion RLSP33PED thermoplastic pedestal sump pump owner's manual 998776; Red Lion pedestal pump product page.
Switch
| Switch type | Adjustable snap-action switch on a float stem |
|---|---|
| On / off levels | On 8 to 10 in, off 3 to 5 in (manual); page lists on at 9 to 11 in |
Figures: Red Lion RLSP33PED thermoplastic pedestal sump pump owner's manual 998776; Red Lion pedestal pump product page.
Build
| Discharge | 1-1/4 in FNPT |
|---|---|
| Intake | Screened opening, top-intake non-clog impeller |
| Construction | Polypropylene pump housing and volute; PBT impeller; zinc-plated steel hardware |
| Power cord | 8 ft, 3-conductor |
| Basin size | 13 in minimum diameter; 18 in to 24 in deep |
| Breaker size | 15 A |
| Carton weight | 16 lb |
| Warranty | 24 months from original purchase |
Figures: Red Lion RLSP33PED thermoplastic pedestal sump pump owner's manual 998776; Red Lion pedestal pump product page.
Versions
Red Lion sells the RLSP33PED as a single model: one voltage, one switch and one column height.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| RL-SP33PED, 1/3 HP, 115 V | 14942052 | Adjustable snap-action float stem, 8 ft cord | View on Amazon |
Figures: Red Lion RLSP33PED thermoplastic pedestal sump pump owner's manual 998776; Red Lion pedestal pump product page; Amazon listing B08NR6MHWL.
Installation and setup
Start by assembling the float stem: thread the float onto the stem about eight turns, slide on the stem guide, push one rubber stopper about 5 in down from the top, clip the guide to the column and pass the stem through the switch lever with the second stopper on top. Then stand the pump level in the centre of a basin at least 18 in deep, on a hard surface rather than clay, earth or gravel. A tilted pump can trap air and wear its bearings.
Red Lion asks for a straight 16 in length of 1-1/4 in pipe threaded directly into the outlet, so flexible joints cannot rub the float stem, then a union above the basin cover. A check valve is recommended where the pipe is long, where the vertical rise passes about 7 to 8 ft, or where the pit is small; with one fitted, drill a relief hole of 1/8 in to 3/16 in below the floor line. Wire it to its own circuit on a 15 A breaker, with GFCI protection where code calls for it.
Switch and sizing notes
A pedestal switch is mechanical and visible. The float rises on its stem, the upper stopper lifts the switch lever and the pump starts; when the water falls, the lower stopper pulls the lever back down. Red Lion's manual gives a start between 8 in and 10 in and a stop between 3 in and 5 in, and you set the stop by sliding the lower stopper.
The flow table falls steeply: 3,300 GPH at 0 ft, 2,800 GPH at 5 ft, 2,040 GPH at 10 ft and only 600 GPH at 15 ft, with shut-off at 16 ft. In practice that limits it to short lifts. Check your total head with the sizing calculator, and read pedestal vs submersible sump pumps if you are unsure which style your pit needs.
Ownership and maintenance
Pedestal pumps sit idle through dry months, so test this one during them. Every three months, check the cord and outlet, clear debris from the basin, look for build-up on the float and stem, and run a cycle. While it runs, a stream should leave the relief hole; if not, clean the hole.
If the motor runs without pumping, Red Lion suggests switching off for about one minute and restarting, repeated a few times, to clear air. The cord cannot be replaced, and opening the motor housing or impeller voids the 24-month warranty, which is claimed through the place of purchase.
Pros and cons
Pros
- Adjustable start and stop through the float stem.
- Motor stays dry above the pit.
- Fits a basin as narrow as 13 in.
- Polypropylene body will not rust.
Cons
- Rated for two hours of running a day or less.
- Only 600 GPH at a 15 ft lift.
- Smaller 1-1/4 in outlet and a 24-month warranty.
Alternatives worth comparing



Compared with and featured in
Final verdict
Choose the RL-SP33PED for a shallow, narrow pit with light, seasonal inflow and a short lift, where an adjustable float and a dry motor are welcome. For frequent pumping or a tall discharge, a cast iron submersible is the better buy.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How long can the Red Lion RL-SP33PED run each day?
Red Lion designs it for domestic household service with total pump run time of two hours or less per day. If your pit fills often enough to exceed that in wet weather, a submersible pump rated for continuous sump duty is the safer choice.
How do I adjust the float on the RL-SP33PED?
Slide the lower rubber stopper on the float stem to change where the pump shuts off. The manual's factory range is a start between 8 in and 10 in and a stop between 3 in and 5 in. Keep the stem clear of the pit wall and the cover.
What size sump basin does the RL-SP33PED need?
The manual calls for a basin at least 13 in in diameter and between 18 in and 24 in deep. Deeper pits put the motor too low on the column, and narrower ones crowd the float stem.
Does the RL-SP33PED need a check valve?
Red Lion recommends one where the discharge pipe is long, the vertical rise passes about 7 to 8 ft, or the pit is small. When you add it, drill the relief hole between the pump and the valve so the pump cannot air lock.