Quick verdict
The 3CDH fits a narrow, shallow pit where the motor is better kept up out of the water and you want to set the start and stop points yourself. Its curve is strong to 10 ft and then collapses to 12 GPM at 15 ft, with no rating at 20 ft. Choose it for short lifts and light to moderate inflow, not for a deep pipe run.
Who it fits, and who should skip it
A good fit if
- Your pit is about 12 in across and at least 18 in deep.
- Your discharge climbs 10 ft or less.
- You want on and off levels you can adjust with rod stops.
- You like the motor sitting above the water where you can see it.
Look elsewhere if
- Your lift approaches 15 ft, where flow falls to 12 GPM.
- Your sump water runs warm for long periods.
- You want a lid-sealed pit with nothing standing above the basin.
Specifications
Motor
| Horsepower | 1/3 HP |
|---|---|
| Voltage | 115 V, single phase |
| Amps | 4.0 A running, 8.1 A inrush |
| Protection | Thermal overload |
Figures: Star Water Systems pedestal sump pump instructions 025472 B, models 3CDH and 5CDH; Star Water Systems column sump pump catalog SW1585 A.
Performance
| Max flow | 58 GPM at 0 ft |
|---|---|
| Flow at 5 / 10 / 15 ft | 52 / 41 / 12 GPM |
| Max head | No rating at 20 ft; last point 12 GPM at 15 ft |
Figures: Star Water Systems pedestal sump pump instructions 025472 B, models 3CDH and 5CDH; Star Water Systems column sump pump catalog SW1585 A.
Switch
| Switch type | Adjustable float and rod switch |
|---|---|
| On / off levels | On at about 10 to 12 in, off at about 2-1/2 in (factory stop setting) |
| Replacement switch | Part 024773 |
Figures: Star Water Systems pedestal sump pump instructions 025472 B, models 3CDH and 5CDH; Star Water Systems column sump pump catalog SW1585 A.
Build
| Discharge | 1-1/2 in |
|---|---|
| Construction | Cast iron base, open non-clogging multi-vane impeller, top suction strainer |
| Dimensions | 10 in wide, 32.25 in tall |
| Power cord | 10 ft |
| Minimum basin | 12 in diameter, 18 in deep |
| Water temperature | Manual: 77 °F continuous; catalog: 130 °F continuous, 150 °F intermittent |
| Circuit | 15 A minimum, GFCI |
| Warranty | 1-year limited |
Figures: Star Water Systems pedestal sump pump instructions 025472 B, models 3CDH and 5CDH; Star Water Systems column sump pump catalog SW1585 A.
Installation and setup
The 3CDH ships partly assembled, and the float rod goes on first. Clamp the rod guide to the column about 6 in below the motor without over-tightening, screw the float onto the rod, pass the rod through the guide, then slide the first rubber stop to about 8 in from the top. Feed the rod through the pump switch and fit the second stop above it. Star estimates the whole job at 20 minutes.
Stand the pump on a hard surface in a clean basin and leave the float room to move. Run discharge pipe no smaller than 1-1/2 in with a check valve, and drill a 3/16 in vent hole to stop air locks. The installation steps put that hole 8 to 12 in above the pump base, pointed down into the pit at 45 degrees and away from the float; a warning page elsewhere says level with the top of the pump, so follow the step-by-step figure. Plug into a grounded GFCI outlet on a dedicated 15 A circuit, never an extension cord, and tape the cord to the pipe.
Switch and sizing notes
With the lower stop 8 in from the top of the rod, the pump starts at roughly 10 to 12 in of water and stops at about 2-1/2 in. Sliding the lower stop up toward the upper one shortens the cycle, which helps in a small pit that refills quickly. The rod must stay vertical and move freely, or the pump may not start.
Read the curve before buying: 52 GPM at 5 ft and 41 GPM at 10 ft are healthy for a 1/3 HP pump, but flow drops to 12 GPM at 15 ft, and Star lists nothing at 20 ft. Add your vertical lift to an allowance for pipe and fittings, then check the result with the sizing calculator. The pedestal vs submersible guide covers when a column pump is the right style.
Ownership and maintenance
Star asks for a check at least every three months: clear debris that could jam the float, then pour in water and watch a full cycle. Heavy mud, sand or pea gravel can clog the impeller; the manual suggests back-flushing through the discharge with a garden hose. Unplug the pump and wait 2-1/2 hours after use before handling it.
The pump is meant for intermittent sump duty, not fountains or continuous running, and must never run dry. The two Star documents disagree on water temperature, so treat warm-water drainage with caution. Warranty is one year from purchase, handled through the dealer, and does not cover freezing damage.
Pros and cons
Pros
- Start and stop levels adjust with rod stops.
- Cast iron base keeps the column steady.
- Fits a basin only 12 in across.
- Replacement switch sold by part number.
Cons
- Flow drops to 12 GPM at 15 ft.
- Only a 1-year warranty.
- Star's two documents conflict on water temperature.
Alternatives worth comparing



Final verdict
The 3CDH is a solid pick for a narrow pit and a short lift, especially if you want to tune the cycle with the rod stops. If your water must climb much past 10 ft, its curve runs out of breath, and a pedestal or submersible with more head is the safer buy.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
What horsepower is the Star 3CDH?
Star lists the 3CDH at 1/3 HP on 115 V single phase, drawing 4.0 A running and 8.1 A at start. Its larger sibling, the 5CDH, is the 1/2 HP version of the same column design with more flow at every height, including a rating at 20 ft.
How do I change when the 3CDH turns on and off?
Move the rubber stops on the float rod. With the lower stop about 8 in from the top of the rod, the pump starts near 10 to 12 in of water and stops near 2-1/2 in. Moving the lower stop closer to the upper one makes the pump cycle on and off sooner.
What size sump basin does the 3CDH need?
Star's manual calls for a basin at least 18 in deep and 12 in in diameter, and the catalog also says it fits a 12 in pit. Make sure the float can travel freely; if it rubs the wall or the inlet pipe, the pump may not run.
How hot can the water be for the 3CDH?
The documents disagree. The current installation manual says continuous water temperature must not exceed 77 °F, while Star's sales catalog lists 130 °F continuous and 150 °F intermittent. Ordinary groundwater stays cool, but let hot discharge from appliances cool before it reaches the pit.