Quick verdict
This is the largest pump in Wayne's CDU sump line and it is meant for basements that take in a lot of water or must push it a long way up. At a 20 ft lift it still lists 3,840 GPH, about what a 1/2 HP CDU800 makes at 10 ft. Most homes do not need that much pump, and an oversized one in a small pit short-cycles, so match it to real inflow first.
Who it fits, and who should skip it
A good fit if
- Your current pump runs for long stretches in heavy rain and still loses ground.
- Water has to climb 15 to 20 ft before it reaches daylight.
- You want a vertical float with a guard in a pit 11 in or wider.
- You value a stainless housing and a five-year warranty.
Look elsewhere if
- Your pit fills slowly; a 1/3 or 1/2 HP pump will cycle far less.
- Your outlet is on a shared circuit that cannot spare 15 A.
- The pit takes laundry water or sediment rather than clear ground water.
Specifications
Motor
| Horsepower | 1 HP |
|---|---|
| Voltage | 120 V, 60 Hz, single phase |
| Motor type | PSC, oil-filled, ball bearings in a sealed oil bath |
| Circuit requirement | 15 A minimum |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU1000 product page.
Performance
| Max flow | 6,100 GPH at 0 ft (102 GPM) |
|---|---|
| Flow at 5 ft | 5,640 GPH (manual prints 5,460) |
| Flow at 10 ft | 5,100 GPH |
| Flow at 15 ft | 4,560 GPH |
| Flow at 20 ft | 3,840 GPH |
| Max head | Not stated on the data sheet (table ends at 20 ft) |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU1000 product page.
Switch
| Switch type | Integrated vertical float switch with float guard |
|---|---|
| On / off levels | On at about 9 in, off at about 4 in |
Figures: Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU1000 product page; Wayne submersible sump pump manual 600002W-001 J.
Build
| Discharge | 1-1/2 in NPT |
|---|---|
| Intake | Top suction, anti-airlock; no weep hole needed |
| Construction | Stainless steel motor housing and fasteners; cast iron volute and seal plate |
| Impeller | Glass-reinforced thermoplastic |
| Power cord | 8 ft SJTW, water resistant |
| Size and weight | 10-1/2 in L x 9 in W x 11 in H; 22 lb |
| Minimum basin | 11 in diameter, 22 in height |
| Approval | CSA agency approved |
| Warranty | 5-year limited, original purchaser |
Figures: Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU1000 product page; Wayne submersible sump pump manual 600002W-001 J.
Versions
Wayne lists the CDU1000 with a vertical float and a CDU1000ET tethered twin. The part number printed on Wayne's sell sheet is shown below.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| CDU1000, vertical float, 120 V | 58321-WYN2 | Integrated vertical float, 8 ft cord | View on Amazon |
| CDU1000ET, tethered float, 120 V | Not on the data sheet | Same 1 HP rating and flow table; needs a 14 in pit | Not linked |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Amazon listing B0062FTMV0.
Installation and setup
A 1 HP pump empties a pit fast, so the basin matters as much as the pump. Wayne's minimum is 11 in across and 22 in tall for this vertical-float model; a wider pit stores more water between starts and spares the motor. Set the pump level on the basin floor or on a block, never on loose soil or gravel, with the float turned away from the drain tile inlet and at least 1 in from the wall.
Wayne requires rigid PVC from the 1-1/2 in NPT outlet and a check valve, which can sit just above the basin for easy removal. The top intake means no weep hole is called for. Secure the cord to the pipe so it cannot foul the float, and plug directly into a GFCI receptacle on a circuit rated for at least 15 A. Outside, carry the water at least 3 ft from the foundation, and slope the line downhill where it might freeze.
Switch and sizing notes
The vertical float runs on a guarded rod. Factory settings start the pump near 9 in and stop it near 4 in, and those points are fixed. At this flow, a small pit drains in moments, so check run time per cycle before you commit.
Wayne's numbers fall gently with height: 6,100 GPH open, 5,100 GPH at 10 ft, 4,560 GPH at 15 ft and 3,840 GPH at 20 ft. That shallow slope is the point of the CDU1000; it suits tall or long discharge runs where smaller pumps fade. Work out your total head with the sizing calculator, then compare it with the CDU980E before paying for the extra horsepower.
Ownership and maintenance
Wayne's routine is the same for the whole CDU family: look in on the pump three to four times a year, stand it upright if it has walked, clear the inlet screen and float, and fill the pit to watch a full cycle. A GFCI that trips in a damp basement leaves the pump dead, so check it on each visit. Allow at least two hours of cooling before handling a pump that has been running.
The warranty runs five years for the original buyer. Claims need proof of purchase and a return authorization number from Wayne before the pump is sent back.
Pros and cons
Pros
- Most flow in Wayne's CDU line at every listed height.
- Keeps 3,840 GPH at a 20 ft lift.
- Top suction resists air lock and pit-floor debris.
- Wayne backs it for five years.
Cons
- Easy to oversize for an ordinary basement pit.
- Needs at least a 15 A circuit.
- Clear water only, with fixed float levels.
Alternatives worth comparing



Final verdict
The CDU1000 is the answer for genuinely heavy inflow or a tall, long discharge run. For a typical basement it is more pump than the pit can feed, so confirm the need with your own numbers before choosing it over the CDU980E or CDU800.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How much water does the Wayne CDU1000 pump at 10 feet?
Wayne lists 5,100 GPH at a 10 ft lift, from 6,100 GPH with no lift. At 15 ft the figure is 4,560 GPH and at 20 ft it is 3,840 GPH. Add pipe friction to your vertical lift before reading the table.
What is part number 58321-WYN2?
Wayne's stainless sump pump sell sheet gives 58321-WYN2 as the CDU1000 pump part number and 58321-WYN3 for the CDU980E. The UPC printed for the CDU1000 on that sheet also matches the listing linked on this page.
Is a 1 HP sump pump too big for my basement?
It can be. A pump that drains the pit in a few seconds starts and stops far more often, which wears the switch and motor. Use the cycle calculator with your pit size and inflow; if a 1/2 HP pump keeps up, it is usually the better choice.
Does the CDU1000 need a check valve?
Yes. Wayne's manual makes a check valve a requirement to stop water flowing back into the pit after each cycle. Thanks to the top-suction design, Wayne says no weep hole is needed below it.