Quick verdict
The CDU980E is the pump for a pit that fills fast or pushes water well above the basement floor. It keeps about four-fifths of its open-pipe flow at a 10 ft lift and still lists 3,500 GPH at 20 ft, so it covers heights where a 1/3 HP pump fades. The trade-offs are a bigger electrical load, a vertical float that needs an 11 in pit, and clear-water duty only.
Who it fits, and who should skip it
A good fit if
- Storms or a high water table keep a smaller pump running for long spells.
- Your discharge rises 15 to 20 ft, where the CDU980E still lists 4,100 and 3,500 GPH.
- Your pit is at least 11 in across and you want a float that cannot hang on a tether.
- You want a five-year warranty on a pump assembled in the USA.
Look elsewhere if
- Your pit is shallow or very small, so a high-flow pump would cycle on and off constantly.
- The water carries mud, sand or grey water; Wayne limits it to clear ground water.
- You cannot give the pump a dedicated circuit of at least 15 A.
Specifications
Motor
| Horsepower | 3/4 HP |
|---|---|
| Voltage | 120 V, 60 Hz, single phase |
| Motor type | PSC, dielectric oil-filled, upper and lower ball bearings |
| Circuit requirement | 15 A minimum |
| Motor protection | Automatic-resetting thermal protector |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU980E product page.
Performance
| Max flow | 5,490 GPH at 0 ft (92 GPM) |
|---|---|
| Flow at 5 ft | 5,076 GPH |
| Flow at 10 ft | 4,600 GPH |
| Flow at 15 ft | 4,100 GPH |
| Flow at 20 ft | 3,500 GPH |
| Max head | Not stated on the data sheet (table ends at 20 ft) |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000.
Switch
| Switch type | Integrated vertical float switch, solid polypropylene float, float guard |
|---|---|
| On / off levels | On at about 9 in, off at about 4 in (factory set) |
Figures: Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne CDU980E product page; Wayne submersible sump pump manual 600002W-001 J.
Build
| Discharge | 1-1/2 in NPT |
|---|---|
| Intake | Top suction; no weep hole needed |
| Construction | Stainless steel motor housing and fasteners, cast iron volute and seal plate |
| Impeller | Glass-reinforced thermoplastic (polycarbonate per the product page) |
| Shaft seal | John Crane carbon/ceramic |
| Power cord | 8 ft SJTW |
| Size and weight | 10-1/2 in L x 9 in W x 11 in H; 22 lb |
| Minimum basin | 11 in diameter, 22 in height |
| Max water temperature | 77 °F |
| Warranty | 5-year limited, original purchaser |
Figures: Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Wayne submersible sump pump manual 600002W-001 J; Wayne CDU980E product page.
Versions
Wayne's manual groups the CDU980E with a tethered-float twin. Only the vertical-float pump is matched to a confirmed direct listing.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| CDU980E, vertical float, 120 V | 58321-WYN3 | Integrated vertical float, 8 ft cord | View on Amazon |
| CDU980ET, tethered float, 120 V | Not on the data sheet | Same 3/4 HP rating and flow table; tether switch Wayne says to replace every two years | Not linked |
Figures: Wayne submersible sump pump manual 600002W-001 J; Wayne stainless steel sump pump sell sheet, CDU980E and CDU1000; Amazon listing B00554SP3K.
Installation and setup
Wayne writes the CDU980E around a basin at least 11 in across and 22 in tall. Clean the pit, then stand the pump directly on the basin floor or on a brick or block, never on clay, gravel or sand. Turn it so the float faces away from the inlet and has at least 1 in of clearance from the wall through its full travel.
The manual requires rigid PVC and a check valve on the 1-1/2 in NPT outlet; flexible hose lets the pump move, and a moving pump can stop the switch working. Wayne's own check valve, part 57028-001, can sit just above the basin so the pump comes out easily. Because the intake is on top, Wayne says no weep hole is needed. Tie the cord to the pipe, plug it straight into a GFCI receptacle with no extension cord or surge strip, and route the outlet so water lands at least 3 ft from the foundation.
Switch and sizing notes
The switch is a vertical float on a guided rod with a solid polypropylene float. It starts the pump near 9 in of water and stops it near 4 in; Wayne does not offer an adjustment. Keep that 5 in band in mind in a narrow pit, because a pump this strong empties it quickly.
Size from the table, not the box. Wayne's manual lists 5,490 GPH at 0 ft, 5,076 at 5 ft, 4,600 at 10 ft, 4,100 at 15 ft and 3,500 at 20 ft. Add vertical lift to an allowance for horizontal pipe and fittings, then read across. If a 1/2 HP model already meets your inflow at that head, it will run longer, gentler cycles. The sizing calculator and the basin cycle calculator help you check both.
Ownership and maintenance
The bearings run in sealed oil, so there is nothing to lubricate. Wayne asks for an inspection three to four times a year: confirm the pump still stands upright, clear debris from the float and inlet screen, reset a tripped GFCI and pour in a bucket of water to watch a full cycle. Skipping that routine can void the warranty. Before any service, unplug the pump and let it cool for at least two hours.
Wayne's product page links float top and float replacement kits for older and newer units. The 5-year warranty covers the original buyer with proof of purchase and needs a return authorization number from Wayne.
Pros and cons
Pros
- Holds 4,600 GPH at a 10 ft lift.
- Top suction keeps pit-floor debris away from the impeller.
- Stainless motor housing over a cast iron volute.
- Five-year limited warranty from Wayne.
Cons
- Clear water only, and Wayne's chart says water above 77 °F can trip it.
- Needs a 15 A circuit and an 11 in pit.
- Float levels cannot be adjusted.
Alternatives worth comparing



Compared with and featured in
Final verdict
Buy the CDU980E for heavy inflow or a tall lift where a 1/3 or 1/2 HP pump runs out of breath. In an ordinary pit with modest lift, a smaller Wayne or Zoeller will cycle less and draw less current.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How many gallons per hour does the Wayne CDU980E pump?
Wayne's current manual lists 5,490 GPH with no lift, 4,600 GPH at 10 ft and 3,500 GPH at 20 ft. The product page prints a slightly different table, so treat the manual's figures as the reference and size from your own total head.
Does the CDU980E need a weep hole?
No. Wayne says the top-suction design prevents air lock, so no weep hole is needed. The manual still requires a check valve in the discharge line to stop water running back into the pit after each cycle.
What size sump pit does the CDU980E need?
The vertical-float version needs a basin at least 11 in in diameter and 22 in tall, with the float clear of the wall by at least 1 in. Tethered models need a wider 14 in pit according to the same manual.
What is the difference between the CDU980E and CDU1000?
They share the stainless housing, cast iron volute, vertical switch and outlet. The CDU980E has a 3/4 HP motor; the CDU1000 has 1 HP and lists 5,100 GPH at 10 ft against 4,600 GPH for the CDU980E.