4 in deep well submersible ยท Flotec

Flotec FP2211 115 V Deep Well Submersible Pump

The Flotec FP2211 is a 1/2 HP, 115 V, 2-wire submersible for 4 in wells. Pentair rates it at 13.2 GPM from 20 ft and 8.1 GPM from 100 ft at 40 psi, with water up to 150 ft deep.

Model FP2211 · part number FP2211 · Updated November 2026

Horsepower
1/2 HP
Voltage
115 V, 60 Hz
Max flow
13.6 GPM maximum capacity
Max head
150 ft maximum depth to water
Discharge
1-1/4 in NPT

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

The FP2211 is a homeowner-grade submersible for a modest drilled well on a 115 V circuit. Its curve is gentle down to about 100 ft, then drops sharply: at 150 ft it manages just 2 GPM at 40 psi. A 115 V motor also asks for a 25 A breaker, so check the circuit and cable before buying.

Who it fits, and who should skip it

A good fit if

  • A 4 in well with water no deeper than about 100 ft.
  • Sites where only 115 V is run to the well.
  • A first submersible replacing an old jet pump.

Look elsewhere if

  • Water near the 150 ft limit, where output nearly stops.
  • Long cable runs better served by a 230 V motor.

Specifications

Motor

Horsepower1/2 HP
Voltage115 V, 60 Hz
Wiring2 wires plus ground
Recommended breaker25 A

Figures: Pentair Flotec FP2211 product page; Flotec 2-wire 4 in submersible sell sheet FP12176RE.

Performance

Max flow13.6 GPM maximum capacity
Max head150 ft maximum depth to water
GPM at 40 psi: 20 / 40 / 60 ft13.2 / 12.2 / 10.9
GPM at 40 psi: 80 / 100 / 150 ft9.6 / 8.1 / 2
Maximum pressure105 psi

Figures: Pentair Flotec FP2211 product page; Flotec 2-wire 4 in submersible sell sheet FP12176RE.

Build

Discharge1-1/4 in NPT
Pump diameter3.78 in
ConstructionStainless steel and thermoplastic; floating stack impellers
Carton weight21 lb
Switch typeNone on the pump; external pressure switch
WarrantyThree years for 4 in submersibles (manual's warranty table)

Figures: Pentair Flotec FP2211 product page; Flotec 2-wire 4 in submersible sell sheet FP12176RE; Flotec 4 in submersible pumps installation manual FP874.

Installation and setup

Pentair's manual for its 4 in pumps sets the pump 15 to 20 ft below the lowest running water level and at least 5 ft above the bottom. Tie a safety rope of at least 5/16 in polypropylene to the discharge eyelet and to the well cap, so the pump cannot be lost down the hole.

Drop pipe depends on depth: 100 psi polyethylene to 100 ft, 160 psi polyethylene to 220 ft. With plastic pipe, seal joints with PTFE tape rather than pipe dope, which can crack plastic. A new well should be developed first so that sand does not lock the impellers.

On first start, Flotec describes a staged procedure with a partly open discharge valve to clear sand; never run the pump against a fully closed valve, which can destroy it and voids the warranty. At the surface, fit a relief valve that passes full flow at 100 psi when the tank is precharged.

Switch and sizing notes

The pump runs from a separate pressure switch. With a precharged tank, set the air 2 psi below cut-in, for example 28 psi with a 30/50 switch, and recheck it yearly. The switch settings guide covers bands.

Flotec's figures are already at 40 psi at the wellhead, which makes sizing easy: find your depth to water and read across. At 60 ft the FP2211 gives 10.9 GPM, enough for a typical house. At 100 ft it is 8.1 GPM. Beyond that, move to the 3/4 HP FP2222. Note too that the 25 A breaker reflects a 115 V motor's higher current; the FP2212 is the same pump on 230 V.

Ownership and maintenance

The manual voids cover for excessive sand, corrosive water, entrained gas or a deadheaded pump, so the well and the valve settings matter as much as the pump. Protect the tank and surface piping from freezing.

If the pump starts too often, the usual cause is a waterlogged tank: adjust the air to 2 psi under cut-in. The manual's warranty table gives 4 in submersibles three years, with the receipt and label required.

Pros and cons

Pros

  • Runs on a 115 V circuit.
  • Performance quoted at 40 psi, ready to use.
  • Floating stack impellers resist sand locking.
  • Two-wire hookup with no control box.

Cons

  • Needs a 25 A breaker.
  • Only 2 GPM at 40 psi from 150 ft.
  • Saved manual is an older series edition.

Alternatives worth comparing

Final verdict

Choose the FP2211 for a moderate-depth 4 in well where 115 V is the only supply. Keep it to wells where the 40 psi table still shows healthy flow, and choose a 230 V or larger model when depth or wiring argue against it.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

How deep can the Flotec FP2211 pump from?

Pentair lists an operating range of 20 to 150 ft depth to water. Output at 40 psi is 8.1 GPM from 100 ft and 2 GPM from 150 ft, so the useful range for a household is roughly the upper hundred feet.

What breaker does the FP2211 need?

Pentair recommends a 25 A breaker for this 115 V model. The 230 V FP2212, with the same pump end, calls for a 10 A breaker, which is one reason most submersibles are 230 V.

Does the FP2211 need a control box?

No. It is a 2-wire pump with two conductors plus ground, so it connects to the pressure switch without a control box. The start components are built into the motor down the well.

What tank precharge should I use?

Set a precharged tank 2 psi below the switch cut-in, so 28 psi for a 30/50 switch. Do not fit bleeder orifices with a precharged tank, and check the air charge once a year.