Quick verdict
The J10S is the JS model for demanding use or a water level near the bottom of the shallow range. It is the only one of the three common sizes that still gives double-digit flow at 40 psi from 25 ft. That extra performance comes with a bigger motor, so it needs a suitable circuit and a tank large enough to avoid short cycles.
Who it fits, and who should skip it
A good fit if
- Large households or small farms on a shallow source.
- Water near 20 to 25 ft down that weaker jets struggle with.
- Homes that water a lawn alongside normal house use.
Look elsewhere if
- Small cottages where a 1/2 HP pump is enough.
- Any well where water drops below 25 ft.
Specifications
Motor
| Horsepower | 1 HP |
|---|---|
| Voltage | 115/230 V single phase, capacitor start |
| Motor details | 3500 RPM, stainless shaft, auto-reset overload |
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy).
Performance
| Max flow | 24.8 GPM at 30 psi, 5 ft lift |
|---|---|
| Max head | 74 psi shut-off at 5 ft of lift |
| 5 ft lift: 40 / 50 / 60 psi | 24.4 / 16.6 / 9.9 GPM |
| 15 ft lift: 30 / 40 / 50 psi | 19.8 / 19.5 / 13.8 GPM; shut-off 70 psi |
| 25 ft lift: 30 / 40 / 50 psi | 12.5 / 12.4 / 10.4 GPM; shut-off 65 psi |
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy).
Controls
| Switch type | AS4 pressure switch, 30-50 psi preset |
|---|
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy).
Connections
| Discharge | 1 in NPT |
|---|---|
| Suction | 1-1/4 in NPT |
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy).
Build
| Nozzle and venturi | AN018 / AD3339 |
|---|---|
| Weight | 50 lb |
| Listing | UL778 listed motor; NSF/ANSI 61 and 372 listed jet pumps |
| Warranty | 1 year from install or 18 months from date code |
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy); Amazon listing B00EEOXYGA; Goulds jet pump installation manual IM102 (third-party copy).
Versions
Goulds lists each JS size as a CSA-listed standard order number or a UL-listed number ending in UL.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| J10S, 1 HP (CSA listed) | J10S | Nozzle AN018, venturi AD3339 | View on Amazon |
| J10SUL, 1 HP (UL listed) | J10SUL | Same pump, UL-listed order number | Not linked |
| J15S, 1-1/2 HP | J15S | 14.0 GPM at 40 psi from a 25 ft lift | Not linked |
Figures: Goulds JS shallow well jet pumps technical brochure BJS+ R4 (distributor copy).
Installation and setup
A 1 HP jet pulls hard on its suction line, so friction and leaks matter more. Keep the run short, use at least 1-1/4 in pipe, and go up a size for offsets beyond 50 ft. The line should slope steadily upward to the pump. Goulds suggests a compound pressure and vacuum gauge on the suction side, which shows at a glance whether a problem is on the well side or the house side.
Hang the foot valve 5 ft or more above the bottom of a clean well. On a low-yield well, a ball valve in the suction line can throttle the pump so it does not draw the water below the foot valve.
At the discharge, fit a tee with a priming port, then run straight to the tank with only a full-port valve in between. Anything restrictive there causes switch chatter, which burns contacts and stresses the motor.
Switch and sizing notes
The AS4 switch ships at 30/50 psi; set the tank 2 psi below cut-in. With this much flow a small tank empties and refills fast, so size it generously using our pressure tank guide.
The J10S makes the most sense at the deep end of the shallow range. From 25 ft it gives 12.4 GPM at 40 psi and even 10.4 GPM at 50 psi, where the J5S manages 6.2 and 1.3 GPM. If the water sits within 10 ft, the smaller pumps cover most homes and the 1 HP motor is overkill.
Ownership and maintenance
Back pullout construction means the motor and impeller come out while the casing stays on its pipes, and a clean-out plug gives access to the nozzle. The seal sits behind a diaphragm that keeps it wet, and the pump re-primes once water rises above the foot valve again.
One retail listing gives the material as stainless steel; Goulds describes an electro-coated casing and composite impeller, so go by the brochure. Warranty cover is one year from installation or 18 months from the date code.
Pros and cons
Pros
- 12.4 GPM at 40 psi from a 25 ft lift.
- Holds 10.4 GPM even at 50 psi from 25 ft.
- Serviceable without disturbing pipework.
- Seal protected against dry running.
Cons
- Oversized for shallow, light-use sites.
- Warranty covers one year only.
- Needs a generous pressure tank.
Alternatives worth comparing



Final verdict
Choose the J10S when the water level sits near 25 ft or demand is heavy, because it keeps real flow at 40 and 50 psi where smaller jets fade. For shallow, light-use sites, a J5S or J7S is the better match.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How much water does the Goulds J10S pump from 25 ft?
Goulds lists 12.5 GPM at 30 psi, 12.4 GPM at 40 psi and 10.4 GPM at 50 psi from a 25 ft suction lift, with a shut-off of 65 psi. That is the strongest deep-lift figure among the common JS sizes.
What is the J10SUL?
It is the UL-listed order number for the same 1 HP pump. Goulds lists each JS size under a CSA-listed number and a UL-listed number ending in UL, so buy whichever your local code or inspector expects.
Is the J10S made of stainless steel?
Goulds' brochure describes an electro-coated casing, a glass-filled composite impeller and a stainless steel shaft and wear ring. A retail listing that calls the whole pump stainless steel does not match the maker's description.
Does the J10S need a suction gauge?
It is not required, but Goulds recommends a compound pressure and vacuum gauge on the suction side. It helps diagnose air leaks, blocked foot valves and excessive lift without taking the pump apart.