Quick verdict
The E75STVT is the pick in this group when a sewage basin takes heavy flow, such as several fixtures at once, and the lift stays under about 15 ft. It moves more water than most 1/2 HP ejectors and carries a five-year warranty. Its documents disagree on a few figures, so read the pump label.
Who it fits, and who should skip it
A good fit if
- Several fixtures drain to one basin and you want capacity in reserve.
- Your lift is 15 ft or less, where Pentair still lists 105 GPM.
- You value a long warranty on a pump you would rather not pull often.
Look elsewhere if
- The lift approaches 20 ft, where the data sheet falls to 40 GPM.
- Your basin is smaller than the 18 in diameter and 30 in depth Flotec recommends.
Specifications
Motor
| Horsepower | 3/4 HP |
|---|---|
| Voltage | 115 V, single phase, 60 Hz |
| Current | 9 A on the data sheet; 11.0 A full load in the manual |
| Circuit | Individual 15 A branch circuit |
| Motor type | PSC, oil-filled, automatic-reset overload |
Figures: Pentair Flotec E75STVT product page; Flotec E75STVT data sheet FP8190RE; Flotec submersible solids handling pumps owner's manual FP893.
Performance
| Max flow | 170 GPM (10,200 GPH) at 0 ft |
|---|---|
| Max head | 24 ft maximum lift |
| Flow at 5 ft | 153 GPM (9,180 GPH) |
| Flow at 10 ft | 125 GPM (7,500 GPH) |
| Flow at 15 ft | 105 GPM (6,300 GPH) |
| Flow at 20 ft | 40 GPM (2,400 GPH) |
Figures: Pentair Flotec E75STVT product page; Flotec E75STVT data sheet FP8190RE.
Switch
| Switch type | Tethered float with piggyback plug |
|---|---|
| On / off levels | On 16.5 in, off 7.5 in (data sheet); product page lists 7-1/2 in and 3 in |
Figures: Pentair Flotec E75STVT product page; Flotec submersible solids handling pumps owner's manual FP893; Flotec E75STVT data sheet FP8190RE.
Build
| Discharge | 2 in FNPT |
|---|---|
| Solids handling | 2 in solids |
| Construction | Cast iron body, rust-proof impeller |
| Power cord | 10 ft |
| Minimum sump | 18 in diameter, 30 in deep |
| Liquid temperature | 32 °F to 70 °F |
| Carton size and weight | 11.5 x 9.88 x 16.13 in, 30 lb |
| Warranty | 5-year limited |
Figures: Pentair Flotec E75STVT product page; Flotec E75STVT data sheet FP8190RE; Flotec submersible solids handling pumps owner's manual FP893.
Installation and setup
Flotec asks for a solid, level footing in a pit of tile, concrete, steel or plastic, at least 18 in across and 30 in deep. Never rest the pump on clay, earth or sand, and pick out gravel that could reach the inlet. A tilted motor can overheat its start switch, so check the pump stands level.
Thread a 2 in pipe into the discharge with PTFE tape rather than pipe dope, which can attack plastic. Fit a free-flowing 2 in check valve in a horizontal run, never angled more than 45° above level and never vertical. Drill a 3/16 in vent hole in the pipe 1 to 2 in above the pump, below the valve, to stop air locks.
For sewage, the manual wants the line at least as large as the discharge, fast enough to keep solids moving at 2 ft per second. A short length of rubber hose near the pump cuts noise and vibration. Plug the float into a grounded outlet on its own circuit, the pump into the float plug, and watch one full cycle.
Switch and sizing notes
The tethered float rises with the basin level and switches the pump through its piggyback plug. Pentair's data sheets print the float turning on at 16.5 in and off at 7.5 in. The current product page lists 7-1/2 in on and 3 in off instead, so take the levels on your float tag as final and leave the arc clear of pipes.
Size from the data sheet's curve rather than the 170 GPM headline: 153 GPM at 5 ft, 125 GPM at 10 ft, 105 GPM at 15 ft and 40 GPM at 20 ft, with nothing left at 24 ft. The manual's own head table lists different figures from the sheet, so where they differ the sheet and product page agree. The sizing calculator works out total head, and the pump type guide explains why a 2 in solids pump suits a toilet line.
Ownership and maintenance
The motor is oiled at the factory and needs no greasing. If the overload trips again and again, the manual points to a stuck impeller, low or wrong voltage, or a motor fault. A hot pump can restart on its own once it cools, so cut the power first.
Before any service, soak the pump in a disinfectant solution for at least one hour. Flotec sells the 10 ft cord as part 21628B046, the tethered float as PW117-267-TSE and the impeller as PS5-273P. The warranty is five years. Do not return a used sewage pump to the store: send the cord tag and receipt.
Pros and cons
Pros
- High capacity: 125 GPM at a 10 ft lift.
- Five-year limited warranty from Flotec.
- Cast iron body passes 2 in solids.
- Repair part numbers for cord, float and impeller.
Cons
- Switch levels and amps differ between documents.
- Liquid range tops out at 70 °F.
- Not sold through a confirmed Amazon listing.
Alternatives worth comparing



Final verdict
The E75STVT earns its place when a sewage basin sees heavy, frequent flow and the lift stays moderate. It outruns typical 1/2 HP ejectors and has the longest warranty here. Read the float tag and wire it to its own circuit.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How much water does the Flotec E75STVT move at a real lift?
Pentair's data sheet lists 153 GPM at 5 ft, 125 GPM at 10 ft and 105 GPM at 15 ft. Flow drops hard after that: 40 GPM at 20 ft and nothing at 24 ft. Plan on the lower rows once pipe friction is added.
Why do the documents disagree on amps and switch levels?
The data sheet prints 9 A and a float range of 16.5 in to 7.5 in. The manual lists 11.0 A full load, and the product page shows 7-1/2 in on and 3 in off. Size the circuit on the higher figure and trust the label.
Can the E75STVT run on an existing outlet?
The manual asks for an individual branch circuit with nothing else on it, protected at 15 A, and rules out extension cords because the voltage drop can stall the pump or damage the motor. A dedicated GFCI outlet near the basin is the tidy answer.
What warranty does the E75STVT carry?
Flotec lists five years for this model, against twelve months for most of its products. Keep the receipt and the cord tag. For an installed sewage pump, Flotec asks you to return the tag and receipt rather than the contaminated pump.