Quick verdict
The RL-WC50TA is a good match for a residential sewage basin of 18 in or wider where the lift to the sewer stays near 10 ft. Red Lion prints a full flow table, so sizing is easy. Its weak spot is height: by 15 ft the flow has already dropped to 1,680 GPH.
Who it fits, and who should skip it
A good fit if
- Your sewage basin is 18 in across or larger, the minimum Red Lion lists.
- The lift to the gravity sewer is about 10 ft, where the table gives 3,720 GPH.
- You want a float on a piggyback plug so the pump can be run by hand for a check.
Look elsewhere if
- The line climbs 15 ft or more; the table falls to 480 GPH at 20 ft.
- Your basin is too narrow for a tethered float to swing clear.
Specifications
Motor
| Horsepower | 1/2 HP |
|---|---|
| Voltage | 115 V |
| Current | 9 A at 115 V |
| Motor type | PSC, dual bearing, with overload protection |
Figures: Red Lion Cast Iron Sewage Pump product page (RL-WC50TA, item 14942748).
Performance
| Max flow | 5,600 GPH at 0 ft |
|---|---|
| Max head | 22 ft shut-off |
| Flow at 5 ft | 4,920 GPH |
| Flow at 10 ft | 3,720 GPH |
| Flow at 15 ft | 1,680 GPH |
| Flow at 20 ft | 480 GPH |
Figures: Red Lion Cast Iron Sewage Pump product page (RL-WC50TA, item 14942748).
Switch
| Switch type | Piggyback tethered float |
|---|---|
| On / off levels | On at 17.5 in, off at 7.5 in |
Figures: Red Lion Cast Iron Sewage Pump product page (RL-WC50TA, item 14942748).
Build
| Discharge | 2 in FNPT |
|---|---|
| Solids handling | Up to 2 in diameter semi-solids |
| Construction | Cast iron, automatic submersible |
| Power cord | 10 ft |
| Minimum basin | 18 in diameter or more |
| Carton size and weight | 9.0 x 8.5 x 18.5 in, 35.5 lb |
| Warranty | Not stated on the product page |
Figures: Red Lion Cast Iron Sewage Pump product page (RL-WC50TA, item 14942748).
Installation and setup
Red Lion links a single manual from this pump's page, and it is written for the RL-WCS50TA basin system built around the same pump. Its steps still show how the maker expects the RL-WC50TA to sit: on the floor of an 18 x 30 in basin, with the float clear of the pump, the plumbing and the basin wall.
Fit the check valve in the horizontal run or at less than 45°, so solids do not settle in a vertical valve and hold it shut. The system kit uses a 2 in discharge pipe, a 3 in vent flange and a 4 in inlet flange, all sealed into a bolted cover with gasket tape; a basin of your own should be just as gas-tight.
Plug the float into the outlet and the pump into the float's piggyback plug. The 10 ft cord should reach a grounded outlet near the pit. Fill the basin with clean water and watch the pump start, empty the basin and stop before you put the cover on.
Switch and sizing notes
The float hangs on its own cord and switches the pump through the piggyback plug. Red Lion lists the pump turning on at 17.5 in and off at 7.5 in, a drawdown of about ten inches. In the basin system the manual mounts the float 4 in above the pump's discharge with a 3.5 in tether, then asks you to confirm the levels against the float's own instructions.
Sizing is simple because Red Lion prints flow at every five feet: 4,920 GPH at 5 ft, 3,720 GPH at 10 ft, 1,680 GPH at 15 ft and 480 GPH at 20 ft, with shut-off at 22 ft. Add your vertical lift to an allowance for pipe length and fittings, then read the row. The sizing calculator helps with total head, and the effluent versus sewage pump guide explains when the 2 in solids passage matters.
Ownership and maintenance
Red Lion pitches this pump at high-volume sewage, effluent and general wastewater, and says it is not for pond use. In a home basin, most service calls start at the float: if it rests on a pipe or gets caught in debris, the pump either never starts or never stops. Turn off the power before reaching in, and clean the float and its cord.
The product page states no warranty term for the pump itself; the basin system manual gives two years for that kit, so ask the seller which terms apply to a loose pump. Keep the item number with your records for parts.
Pros and cons
Pros
- Full flow table every five feet up to shut-off.
- Cast iron body passes 2 in semi-solids.
- PSC dual bearing motor with overload protection.
- Clear minimum basin size in the maker's table.
Cons
- Flow drops steeply above 10 ft of lift.
- Warranty term not printed on the product page.
- Only manual linked is for the basin system.
Alternatives worth comparing



Final verdict
The RL-WC50TA is a sensible ejector for an ordinary basement sewage basin with a lift around 10 ft, and its printed flow table makes sizing honest. For taller lifts or a narrow basin, look at a bigger pump or one with a built-in switch.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is 14942748 the same pump as the RL-WC50TA?
Yes. Red Lion's product table lists model RL-WC50TA with item number 14942748. Retailers often sell it under the item number alone, so search both when you shop or order parts, and match the number on the pump's label.
What basin size does the RL-WC50TA need?
Red Lion lists a minimum basin diameter of 18 in. The basin system that uses this pump comes with an 18 x 30 in tank, which gives the tethered float room to swing without touching the wall or the discharge pipe.
Can it pump effluent from a septic tank?
Red Lion names sewage, effluent and general wastewater on the product page. Septic setups vary, so follow your local code and the system designer on pump placement, screening and alarms before you use any sewage pump in a tank.
How much does the pump weigh?