Check valve ยท PumpSpy

PumpSpy CV-150 Silent Check Valve

The PumpSpy CV-150 is a clear-bodied silent check valve with a spring-loaded flapper, Buna-N rubber couplings and stainless clamps for 1-1/2 in Schedule 40 pipe.

Model CV-150 · part number 93100-01 · Updated November 2026

Flapper
Spring-loaded, to stop water hammer
Body
Clear ABS
Pipe size
1-1/2 in Schedule 40 (the title also says 2 in)
Couplings
Buna-N rubber with stainless steel clamps

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

An easy swap for a noisy or worn check valve: cut a gap of about 5-1/8 in, slide on the couplings and tighten the clamps, with no cement. The clear body shows at a glance whether water is moving. Clamp-on couplings are less rigid than a glued joint, so support the pipe above and below the valve.

Who it fits, and who should skip it

A good fit if

  • You want to replace a noisy check valve without gluing.
  • The discharge is 1-1/2 in Schedule 40 pipe.
  • You like to see that the pump is actually moving water.

Look elsewhere if

  • Your pipe is a different size; the listing title is inconsistent on size.
  • You want a solvent-welded, rigid joint.

Specifications

Design

FlapperSpring-loaded, to stop water hammer
BodyClear ABS

Figures: Amazon listing B091V2WDJ3 (PumpSpy CV-150).

Fit

Pipe size1-1/2 in Schedule 40 (the title also says 2 in)
CouplingsBuna-N rubber with stainless steel clamps
Gap needed5-1/8 in

Figures: Amazon listing B091V2WDJ3 (PumpSpy CV-150).

Build

Size and weight (description)8.5 x 3 x 3 in, 12.8 oz
Maker part number93100-01
Pressure ratingNot stated by the seller

Figures: Amazon listing B091V2WDJ3 (PumpSpy CV-150).

Installation and setup

Unplug the pump and cut out a 5-1/8 in section of the discharge pipe at a height you can reach, or remove the old valve. Slide a coupling onto each pipe end, set the valve between them with its flow arrow pointing away from the pump, and tighten the stainless clamps evenly. Support the pipe so the rubber couplings carry no bending load. Fill the pit and watch the first cycle through the clear body: water should rush up while the pump runs, and the flapper should close quietly when it stops.

Keep a relief hole in the pipe below the valve if your pump maker calls for one.

Compatibility

The description specifies 1-1/2 in pipe, and the included couplings fit 1-1/2 in Schedule 40. The listing title, though, ends with 2 inches, so measure your pipe and expect the 1-1/2 in size. It suits sump, laundry and drainage pumps of any brand on that pipe size. The seller gives no pressure rating, which matters little for household lifts but rules out pressure systems. For a comparison of check types, see the check valve guide.

Ownership and maintenance

The clear body makes checks simple: glance at it during a pump cycle to confirm flow. If water drains back into the pit after the pump stops, debris may be holding the flapper open; loosen the clamps, lift the valve out and rinse it. Retighten the clamps after the first few weeks, as rubber couplings can settle. A cracked or cloudy body is a sign to replace the valve before it splits under the weight of the water column.

Pros and cons

Pros

  • Clear body shows flow and flapper action.
  • Spring closure cuts water hammer noise.
  • Clamp-on fitting, no cement needed.

Cons

  • No pressure rating from the seller.
  • Listing is inconsistent on size and weight.

Alternatives worth comparing

Final verdict

Pick the CV-150 for a quick, glue-free fix to a noisy check valve on 1-1/2 in pipe, with the bonus of seeing the flow. Support the pipe well around the rubber couplings.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

What size pipe does the PumpSpy CV-150 fit?

The description and the included couplings are for 1-1/2 in Schedule 40 pipe. The listing title mentions 2 inches, which conflicts, so measure your pipe and treat 1-1/2 in as the confirmed size.

Why does the CV-150 have a clear body?

So you can see what is happening. During a cycle you should see water moving up through the valve, and when the pump stops the flapper should close. That makes it easy to spot a clog or a pump that is not pumping.

Does the CV-150 stop the bang when my pump shuts off?

That is its purpose. The spring-loaded flapper closes as the flow stops, before the water column can slam it, which is what causes the thump in ordinary swing check valves.

How big a gap do I need to cut?

The seller says it fits within a 5-1/8 in gap. Measure twice before cutting, and leave the pipe ends square and clean so the rubber couplings seal properly against the pipe.