Quick verdict
Small enough to sit inside a narrow or crowded pit, and it comes with its own weep hole already drilled, so there is no separate hole to remember. The catch is its low rating: Zoeller limits it to 10 ft of head and vertical mounting. For tall discharge runs, a solvent-weld or union check rated for more pressure is the safer choice.
Who it fits, and who should skip it
A good fit if
- The pit is narrow or holds two pumps side by side.
- The lift above the valve is no more than 10 ft.
- The pump has a threaded 1-1/2 in discharge.
Look elsewhere if
- The static head above the valve is more than 10 ft.
- The valve must sit on a horizontal run.
Specifications
Rating
| Pressure rating | 4.3 PSI, 10 ft (3 m) of head maximum |
|---|
Figures: Zoeller catalog FM0532, valves section (Inline 30-0238).
Fit
| Connection | Threads into the pump discharge; rubber coupling to the pipe |
|---|---|
| Size | 1-1/2 in |
| Orientation | Vertical installation only |
Figures: Zoeller catalog FM0532, valves section (Inline 30-0238); Amazon listing B00WUFXGT0.
Build
| Weep hole | Pre-drilled |
|---|---|
| Clamps | Stainless steel |
| Listing size | 3 x 2.5 x 1.5 in, 3.2 oz |
| Item number | 30-0238 Inline |
Figures: Zoeller catalog FM0532, valves section (Inline 30-0238); Amazon listing B00WUFXGT0.
Installation and setup
Unplug the pump and thread the valve into the pump's discharge, then slide the riser pipe into the rubber coupling and tighten the stainless clamps. The valve must stand upright: Zoeller lists it for vertical installation only. Because the weep hole is already drilled, do not add a second one, but make sure the hole stays below the basin cover where its spray falls back into the pit. Run the pump through a cycle and watch for leaks at the coupling.
Keep the static head above the valve within 10 ft. Zoeller's install sheet also asks for a union in the line so the pump can come out without cutting pipe.
Compatibility
The 30-0238 suits sump and effluent pumps with a threaded 1-1/2 in discharge, and the listing confirms that size. Zoeller's catalog groups it with low-pressure fittings rated to 4.3 PSI, so it belongs on short residential lifts, not on tall stacks or force mains. Where the run is longer, look at the maker's solvent-weld quiet checks, which carry far higher ratings. The check valve guide compares the main types.
Ownership and maintenance
Check the weep hole whenever you clean the pit; a blocked hole lets air lock the pump, which then runs without moving water. Listen for the flapper closing after each cycle. A valve that lets water run back into the pit makes the pump pump the same water twice, so replace the valve if the pit refills from above after the pump stops.
Pros and cons
Pros
- Very compact; suits tight or dual-pump pits.
- Weep hole comes pre-drilled.
- No glue or threading of the pipe.
Cons
- Limited to 10 ft of head.
- Must be mounted vertically.
Alternatives worth comparing



Final verdict
The 30-0238 is the tidy choice for a cramped pit with a short, vertical lift. Respect its 10 ft limit and choose a higher-rated check valve for anything taller or horizontal.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How high can the water rise above the Zoeller 30-0238?
Zoeller's catalog rates it at 4.3 PSI, which equals 10 ft of head, and warns against more than 10 ft of static head above the valve. Taller discharge pipes need a higher-rated valve.
Do I still need to drill a weep hole?
No. The 30-0238 has a pre-drilled weep hole. Keep it below the basin cover and clear it during routine pit cleaning so air can escape and the pump does not air lock.
Can the 30-0238 be mounted horizontally?
No. Zoeller lists it for vertical installation only. If the valve has to sit on a horizontal run, choose one of the maker's checks that are rated for both orientations.
Will the 30-0238 fit a non-Zoeller pump?
It threads into a 1-1/2 in pump discharge, so it suits most residential sump pumps with that outlet size, whatever the brand. Check your pump's discharge size and thread before ordering.