Quick verdict
A good replacement float when the pump is a little heavier than the 10 A switches allow. The seller ties it to emptying duty only, so it cannot fill a tank. Its own listing disagrees with itself on sewage use and on cycle life, which is worth knowing before you put it in a grinder pit.
Who it fits, and who should skip it
A good fit if
- Your 120 V pump draws more than 10 A but no more than 13 A.
- You need a plain pump-down float with a piggyback plug.
- The pit has room for a tethered float to swing.
Look elsewhere if
- You need the switch to fill a tank rather than empty it.
- The pump runs continuously, which the listing excludes.
Specifications
Electrical
| Switch type | Tethered float, piggyback plug, pump-down (emptying) |
|---|---|
| Voltage | 120 V AC |
| Rating | Up to 1/2 HP or 13 A |
| Cord | 10 ft tether with piggyback plug |
Figures: Amazon listing B01BEHQVEQ (Water Boss piggyback float).
Build
| Float body | Polypropylene, IP68 per the listing title |
|---|---|
| Switch element | Microswitch, mercury-free |
| Cycle life claim | Bullets say over one million cycles; the description says 100,000+ activations |
| Part numbers on the listing | Mfr part SA-3100-10; model row SA-3100-3-RAW |
| In the box | Float switch, user manual, cable ties |
| Weight | 12 oz |
Figures: Amazon listing B01BEHQVEQ (Water Boss piggyback float).
Installation and setup
Fix the cord to the discharge pipe with the supplied cable ties or a hose clamp, leaving enough free tether for the float to swing up and down without touching the pump, the basin wall or the inlet. The free length sets how far the water rises before the pump starts. Plug the float into a grounded 120 V outlet and the pump into the back of the plug. If the pump has an automatic switch of its own, hold it on or switch the pump to manual so only the float decides. Run the pit through several full cycles before you close it.
Compatibility
The listing states the switch works with most sump pumps and motors up to 1/2 HP or 13 A on 120 V AC, for intermittent duty. The title names grinder, septic and sewage pumps, yet the seller's own comparison chart lists this Water Boss piggyback for clear water up to septic effluent and points sewage work to its Sludgeboss floats. Use it on sump, drain and effluent pumps, and choose a sewage-rated float for raw sewage. The switch types guide covers the trade-offs.
Ownership and maintenance
Check the float's swing path whenever you open the pit, since a float resting against a pipe will not lift. Rinse off silt and soap film, and pour in water every few months to see a full start and stop. If the pump hums but the float clicks normally, the fault is in the pump, not the switch. A float that stays up with the pit empty usually has water inside and needs replacing.
Pros and cons
Pros
- Higher amp rating than most universal floats.
- Piggyback plug, so no wiring.
- Polypropylene float body resists corrosion.
Cons
- Listing contradicts itself on sewage use and cycle life.
- Emptying duty only; it cannot fill a tank.
Alternatives worth comparing



Final verdict
Choose this Water Boss float for a 120 V sump or effluent pump that outgrows a 10 A switch. Keep raw sewage for a float the seller rates for it.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Is SA-3100-10 the right part number?
The listing shows two numbers: SA-3100-10 as the manufacturer part and SA-3100-3-RAW as the model row. Both point to the same Water Boss piggyback float with a 10 ft cord, so use either when asking the seller.
Can this float control a sewage ejector pump?
The title says yes, but the seller's chart reserves sewage for its Sludgeboss floats and lists this one for clear water to septic effluent. For raw sewage, follow the chart rather than the title.
What size pump can it switch?
The listing gives 1/2 HP or 13 A at 120 V. Read the amps on your pump's nameplate and stay within that figure, allowing for the higher draw some pumps show at start-up.
Will it work as a fill switch for a tank?
No. This piggyback version is described for emptying only. The wire-lead Water Boss sold as the 2359 can be wired to empty or fill, which suits tanks, cisterns and similar jobs.