The EEAUP250 suits jobs where water keeps coming back and nobody wants to babysit a pump: a leaky window well, a flat roof, a crawl space puddle. The iSwitch has no float to snag and shuts the pump off when it stops moving water. Wayne is clear that it is not a sump pump, the warranty is one year, and the paperwork contradicts itself on cord length and outlet size.
Who it fits, and who should skip it
A good fit if
- Water collects in a window well, crawl space or flat roof between rain storms.
- You want automatic shut-off so the pump cannot run dry.
- You prefer a sensor with no moving float that debris could jam.
- You need more flow than a small manual pump, with 1,600 GPH listed at 10 ft.
Look elsewhere if
- You need a sump pump for a basement pit; Wayne says that voids the warranty.
- Water must be pumped from a septic tank or underground vault.
- You want a warranty longer than one year.
Specifications
Motor
| Horsepower | 1/4 HP |
|---|---|
| Voltage | 120 V, GFCI-protected outlet |
| Motor type | Oil-free |
Figures: Wayne EEAUP250 sell sheet; Amazon listing B00502AIUU; Wayne EEAUP250 owner's manual 620005-001 C.
Performance
| Max flow | 3,100 GPH at 0 ft |
|---|---|
| Flow at 5 / 10 ft | 2,350 / 1,600 GPH |
| Flow at 15 / 20 ft | 900 / 250 GPH |
| Max head | Not stated in text; the sell sheet table ends at 20 ft |
Figures: Wayne EEAUP250 sell sheet.
Switch
| Switch type | iSwitch electronic water sensor, auto on/off |
|---|---|
| On level | 1-3/4 in of water |
| Off level | About 3/8 in (manual); listing says 1/2 in |
| Dry-run protection | Shuts down when it senses water is no longer being removed |
Figures: Wayne EEAUP250 sell sheet; Wayne EEAUP250 owner's manual 620005-001 C; Amazon listing B00502AIUU.
Build
| Discharge | 1-1/4 in NPT with garden hose adapter (manual) |
|---|---|
| Construction | Thermoplastic, centrifugal impeller, bottom suction |
| Power cord | 9 ft (manual); 8 ft (sell sheet) |
| Size and weight | 6-1/2 x 6-1/2 x 9-1/2 in; 11 lb |
| Warranty | 1-year limited |
Figures: Wayne EEAUP250 owner's manual 620005-001 C; Wayne EEAUP250 sell sheet.
Versions
One version is sold, with the iSwitch built in and a garden hose adapter in the box.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| EEAUP250, auto on/off | 57729-WYN1 | 1/4 HP, iSwitch sensor, 1-1/4 in NPT outlet | View on Amazon |
Figures: Wayne EEAUP250 sell sheet; Amazon listing B00502AIUU.
Installation and setup
The outlet is a 1-1/4 in NPT connection. Thread pipe or a fitting straight on, or fit the supplied elbow and garden hose adapter for light jobs. Wayne asks for a hose washer on the garden hose, calling it necessary for correct operation, and recommends unwinding the hose fully before starting.
Set the pump on a hard, flat surface in the water, never directly on mud or sand, which clog the inlet. It must stay upright: the water detection only works when the pump stands the right way up, so do not let it tip over on a slope. Plug into a 120 V GFCI outlet with a polarized, grounded plug. If the pump will live outside, shelter it from sun, rain, snow and freezing, since water left inside can freeze and damage the pump and hose.
Switch and sizing notes
The iSwitch replaces a float. Once water reaches 1-3/4 in, the pump starts, waits 2 seconds to let air out of the chamber, and pumps until the water is down to about 3/8 in. It will not restart until the level is back at 1-3/4 in, and it stops itself if it senses that water is no longer being removed. Wayne warns against bypassing the detector, which would let the seal run dry.
Wayne's sell sheet lists 3,100 GPH at 0 ft, 2,350 at 5 ft, 1,600 at 10 ft, 900 at 15 ft and 250 at 20 ft. That table is word-for-word the same as Wayne's figures for the manual RUP160, so treat it as a family rating. The sizing calculator estimates your total head before you rely on those numbers.
Ownership and maintenance
Before each use, look the pump over: Wayne says not to use it if any part of the housing, switch probe or cord is cracked, broken or missing. Keep the inlet clear, and wipe the sensor area clean of silt so the iSwitch reads the water correctly. If the pump will not start in deep water, check that it is upright and that the outlet has GFCI power.
Wayne covers the EEAUP250 for one year from purchase, with the receipt required. Using it as a sump pump, or in septic tanks and vaults, falls outside the warranty, so pair a real sump pump with your pit and keep this one for the jobs around it.
Pros and cons
Pros
- Starts and stops itself with no float to snag.
- Shuts off when it senses no water moving.
- Wide 1-1/4 in NPT outlet plus a hose adapter.
- Strong rating for 1/4 HP: 1,600 GPH at 10 ft.
Cons
- Not approved for sump pit use.
- One-year warranty from Wayne.
- Maker papers disagree on cord length and outlet.
Alternatives worth comparing



Compared with and featured in
Final verdict
The EEAUP250 is a good choice for recurring puddles in window wells, crawl spaces and on roofs, where an automatic pump with dry-run protection saves trips. Keep it out of the sump pit, and look at the WaterBUG AUTO if a longer warranty matters.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
At what water depth does the Wayne EEAUP250 turn on and off?
Wayne's manual says it starts once water reaches 1-3/4 in and stops at roughly 3/8 in above the hard surface. A retail listing gives the off point as 1/2 in. It will not restart until the water rises to 1-3/4 in again.
Can I use the EEAUP250 as a sump pump?
No. Wayne's manual says the unit is not designed for sump use and that doing so voids the warranty. It also rules out septic tanks and underground vaults. Use a purpose-built sump pump in a basement pit.
Will the EEAUP250 run dry if I leave it plugged in?
It is designed not to. The iSwitch shuts the pump down when water is no longer being removed, so you do not need to unplug it after each job. Keep it upright, since the sensor only works that way.
Why won't my EEAUP250 start?
The water must be at least 1-3/4 in deep for the pump to cycle and prime. Also check that it stands upright on a hard surface, the GFCI has not tripped, and nothing is cracked around the housing or switch probe.