Quick verdict
Read the fine print before buying this tank. VEVOR's own listing says it is not suitable for drinking water, is not frost-proof and must not be connected to a public water supply. That rules it out for a home's potable well system, whatever the title suggests. It may suit irrigation or other non-drinking uses.
Who it fits, and who should skip it
A good fit if
- Irrigation or garden systems that carry no drinking water.
- Small non-potable pump setups needing a 1 in connection.
- Installs in a sheltered spot that never freezes.
Look elsewhere if
- Any household drinking water system, per the listing.
- Connection to a public water supply, which the listing forbids.
Specifications
Capacity
| Tank size | 14 gallons |
|---|---|
| Drawdown | Not stated on the data sheet |
Figures: Amazon listing B0HK71T3BB (VEVOR ET-60LH).
Pressure
| Factory precharge | 29 psi |
|---|---|
| Maximum pressure | 116 psi |
| Working temperature | Up to 194 °F (listing) |
Figures: Amazon listing B0HK71T3BB (VEVOR ET-60LH).
Connection
| Connector | 1 in NPT |
|---|
Figures: Amazon listing B0HK71T3BB (VEVOR ET-60LH).
Build
| Body | Thickened carbon steel |
|---|---|
| Orientation | Horizontal (per part number field) |
| Weight | 20.9 lb |
Figures: Amazon listing B0HK71T3BB (VEVOR ET-60LH).
Use limits
| Drinking water | Not suitable for drinking water (listing) |
|---|---|
| Frost | Not frost-proof |
| Relief valve | Required, not included |
Figures: Amazon listing B0HK71T3BB (VEVOR ET-60LH).
Installation and setup
The listing asks for a relief valve, which is not included, so the system cannot exceed the tank's 116 psi rating. Install the tank where it cannot freeze; the seller notes it is not frost-proof. Check the air charge with a tire gauge before filling and set it 2 psi below your switch's cut-in.
The part number describes a horizontal tank, so plan for a flat base or a pump mounted on top rather than a tall vertical footprint. Add unions and a shut-off valve so the tank can be removed later without draining the whole system.
Compatibility
The 1 in NPT connector suits a standard tank tee, and the 29 psi precharge sits just below the 30 psi cut-in of a common 30/50 switch, which is the usual rule of 2 psi under cut-in. For a different switch band you would adjust the air charge accordingly.
Compatibility ends at the plumbing, though. VEVOR's listing states plainly that the tank is not suitable for drinking water and must not be connected to a public supply, so it should not go into a household well system that feeds taps. For a drinking water tank with published drawdown figures, look at the Amtrol WX-202, and read the tank sizing guide before choosing.
Ownership and maintenance
Check the precharge each season with the pump off and the tank drained. A tank that loses air repeatedly, or shows water at the air valve, has a failed diaphragm and needs replacing. The listing gives no warranty term and no drawdown figure, so judge pump cycling on your own system. If the pump starts every time a tap opens, the air charge is the first thing to check.
Pros and cons
Pros
- Compact 14-gallon size for tight spaces.
- Precharged to 29 psi for a 30/50 switch.
- Standard 1 in NPT connection.
Cons
- Not suitable for drinking water, per the listing.
- No drawdown figure or warranty term published.
- Not frost-proof; relief valve sold separately.
Alternatives worth comparing



Final verdict
The VEVOR ET-60LH may serve a non-potable irrigation setup, but its listing rules it out for drinking water. For a household well, choose a tank listed for potable use with published drawdown.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
Can I use the VEVOR 14-gallon tank for drinking water?
No. VEVOR's own listing says the tank is not suitable for drinking water, is not frost-proof and should not be connected to the public water supply. Use a tank listed for potable water, such as an NSF/ANSI 61 listed model, for a house supply.
What is the precharge of the ET-60LH?
The listing gives 29 psi, which suits a 30/50 pressure switch. Set it with the tank empty and the pump off, and adjust it to 2 psi below cut-in if you use a different switch band.
Does it come with a relief valve?
No. The listing reminds buyers to fit a proper relief valve, sold separately, to protect the tank from over-pressure. Its stated maximum internal pressure is 116 psi, so choose a valve that opens below that.
How much water does it deliver between pump starts?
VEVOR does not publish a drawdown figure. Drawdown is always much smaller than the tank's size, since the air charge takes up most of the volume, so expect only a few gallons per cycle.